Configuring Camera Features 3-11
In addition:
· When AGC Off is the current setting, the Max Gain and Limit fields are not displayed.
· When AGC On is the current setting, the Max Gain field is displayed and may be
modified. The Limit field is not displayed.
· When Open Shutter is the current setting, both the Max Gain and Limit fields are
displayed and may be modified.
Configuring AGC and Open Shutter Settings
Tip: The current IR mode setting affects which AGC Gain and Open Shutter settings are
available. The Relationship between IR Mode and AGC and Open Shutter Settings chart on
page 3-10 describes which settings are available.
1. Select Camera Functions from the Dome Configuration Menu.
2. Move the highlight to AGC/Shutter mode field. The highlight appears in the first field
(AGC/ Mode).
3. Select one of the following:
· Select AGC On to set AGC to automatic mode. This allows you to adjust the
maximum AGC gain setting (in decibels). Continue with step 4.
· Select AGC Off to set the AGC to minimum level. You cannot adjust the maximum
AGC gain or shutter limit settings. Continue with step 7.
· Select Open Shutter to enable field integration. This allows you to adjust the
maximum AGC gain and shutter limit settings. Continue with step 4.
The default setting is Open Shutter.
4. Move the highlight to Max Gain field. Change the setting. The following settings are
available:
· For NTSC cameras, the setting values range from 0 to 28dB.
· For PAL cameras, the setting values range from 0 to 29dB.
5. If you need to change the shutter limit setting, continue below. Otherwise, continue with
step 7.
6. Move the highlight to the Limit field. Change the setting. The following settings are
available:
· For NTSC cameras, the setting values range from 1/2 to 1/60.
· For PAL cameras, the setting values range from 2/3 to 1/50.
The default setting is 1/4 for NTSC and 1/3 for PAL.
7. Select Exit. The Dome Configuration Menu appears. Continue with What To Do Next