Operator`s manual

SensorNet and RS-422 Command Summary A-3
Supported Controllers
The following SensorNet and RS-422 controllers are compatible with SpeedDome Ultra VI:
Controller Protocol Presets Patterns Address Range
VM8 SensorNet None None
1
1-8
VM16/VM16+/
ADTT16/ADTT16E
SensorNet 96 3 1-16
VM32/VM32E/
AD32/AD32E
SensorNet 96 3 1-32
VM96
2
SensorNet or
RS-422
Unlimited 3 1-96
Touch Tracker 16
Elite (VCTT16E)
SensorNet 96 3 1-224
3
VM1 RS-422 4 3 1-58
3
AD2083-02A
AD2083-02B
RS-422 16
4
3 1024 Max.
3, 5
Controller dependent.
SensorNet to RS-422
Converter
6
RS-422 4 3 32 Max.
3
Controller dependent.
AD168 SensorNet
RS-422
96 3 1-168 (SensorNet)
1-99 (RS-422)
AD48 SensorNet
RS-422
96 3 1-48
This list of controllers is complete as of the time of publication. Other controllers may be
supported. Contact your Sensormatic Representative for current information.
1
Only the default Apple Peel pattern is available.
2
VM96 uses “virtual views.” Preset information is stored by the host, not the dome.
3
Additional equipment is required to achieve these numbers.
4
Preset information is stored by code translator, not the dome.
5
A dome address within each group of 64 or 99 cameras is reserved as a global broadcast address.
6
SensorNet to RS-422 Converter allows SensorNet controllers (VM16/VM32 or equivalent) to operate RS-422 domes.