Operator`s manual
B-4 SpeedDome Ultra VI Operator's Manual
Supported Controllers
The following Manchester controllers are compatible with SpeedDome Ultra VI:
Controller Presets Patterns Address Range
AD2150 64 3 1-64
AD48 64 3 1-64
AD168 64 3 1-64
AD2050/2052 64 3 1-64
This list of controllers is complete as of the time of publication. Other controllers may be
supported. Contact your Sensormatic Representative for current information.
Performance Notes
The following considerations should be made when using the SpeedDome Ultra VI camera
dome in a Manchester environment.
Using Auxiliaries
The dome provides four connections for auxiliaries. When used on a Manchester network,
Auxiliaries 1 through 3 are supported. Auxiliary 4 is not supported.
Alarm Inputs
When operating on a Manchester network, the dome can be programmed to respond to any of
the four available alarm inputs. However, the dome cannot transmit alarm input states to the
host controller. If transmitting the alarm input states to the host controller is required, the
alarm device must be wired directly to the host controller.