User's Manual
Page 18 µltraWaveProductguide
Silver Network wiring connections
Silver Network specifications
• Data rate - fixed 57.6 k bps
• Maximum 32 devices spread over up to 4 independent network loops
• Two communication Channels (Side A, Side B)
• Network termination - not required
• Transmission media/maximum separation distances between μltraWave receivers:
EIA-422 copper wire - 1.2 km (0.75 mi.)
Multimode fiber optic cable - 2.2 km (1.4 mi.) - 2 fibers per Channel
Singlemode fiber optic cable - 10 km (6.2 mi.) - 2 fibers per Channel
Note A network interface card must be installed on the μltraWave
receiver to enable network communications.
Figure 13 Receiver unit Silver Network wiring connections
Note Senstar strongly recommends the use of low capacitance
shielded twisted pair data cable for EIA-422,
62.5/125 multimode fiber optic cable, and
9/125 singlemode fiber optic cable.
B-side data path connections *
ground connection
T3 power input (see Figure 10)
(12 to 48 VDC)
T6 input/output (see Figure 10)
AUX input
output 1
output 2
A-side data path connections *
NIC mounting hardware (X 3)
T1 expansion header (solder side)
plug into T1 on PCB
use single point grounding
connect one end of the shield, trim
back the other end and leave it
disconnected
*