7.0 Operating the RU00-M08
Once the required hardware connections are made to the RU00-M08, the unit can be operated with
simple software routines running on the OEM’s host processor. The host software issues
commands to configure the reader, set the reader’s idle mode and to start and stop various Gen2
RFID reader operations.
An example of the sequence of events starting at reader power-up is:
1. Apply DC48V +/- 10% power to the RU00-M08.
2. Establish a connection to the device via the host software.
3. Configure the reader. Critical parameters are:
a. Region of operation
When configured for a specific region, the RU00-M08 can operate only according to the air
interface standards for that region. Key communication parameters are not adjustable by the
user but are inherent in the RU00-M08 firmware. The FCC regional operation is the default for
the device.
NOTE: The OEM is strictly forbidden to operate the RU00-M08 in a regional mode other than
that in which the device is located. Applicable agency certification must be obtained by the
OEM for their product to operate in the region in which it is located. The modular certification of
the RU00-M08 in the U.S. may only be utilized by OEM’s that follow all guidelines set forth in
this document.
b. RF output power
The RU00-M08 output power must be set to a level between 10 and 30dBm. The default power
is set to the reader’s maximum allowable of 30dBm.
4. Initiate an RFID operation.
Gen2 RFID operations including Inventory, Read, Write, Lock and Kill are initiated with a command.
5. Set the RU00-M08 standby mode.
When the RU00-M08 is not executing an RFID operation, it assumes a low power state until another
RFID function is initiated by the host.
6. Antenna setup
The module arranges the antenna to use the vertical setting.