User's Manual

AMR-XXX
2. Perform a TouchRead on TouchPad(s) to insure TouchRead to
the encoder works.
3. Place the remote TouchPad Cover firmly over the Sensus
TouchPad until secured.
4. Once the TouchPad Cover is secured on the TouchPad, find a
location close to the TouchPad Cover to install the MXU.
5. Place the MXU at the location for installation, with the door open,
mark the location to pre-drill the holes designed to fasten the
unit to the wall. (Fastener holes are located above the battery).
6. Remove the MXU from the wall and use a 1/4" drill bit to pre-drill
the fastener holes.
7. Place the unit on the wall and align the pre-drilled holes with the
fastener locations.
8. Secure the unit to the wall with screws.
9. Connect the wires from the TouchPad Cover to the coordinating
port terminals in the MXU labeled TouchCoupled.
Note: Red and black wires are non-polarized.
10. Once all the connections are complete, close the door of the
MXU and tighten security screw until unit is firmly sealed.
11. Once the units are secured, begin the activation process. (See
Activate Radio section).
BATTERY
Blue
Black &
White
Red
Green
Black
Red
Green
Black
RadioRead
PORT 1
PORT 2
Touch
Coupled
Touch
Coupled
Sensus Metering Systems Uniontown, PA 15401
Model 510R Pt. No. 539-61-537-51006T
M510R-D2-CMB-CMB-T
Patent Pending. Date 06/05
Dual Port TouchCoupler Installation
Wire stripping tool
Screwdriver - Small standard head for terminal connections
SR II security screw socket with 1/4" nut driver or ratchet wrench
Power drill and bit (1/4")
8 x 1" sheet metal screws
1. Perform a TouchRead on TouchPad(s) to insure TouchRead to
the encoder works.
2. For new installations of dual ports, nd a suitable location for an
installation where two TouchPads can be installed that will be free
from interference. The optimum distance should be less than 12"
otherwise wires may require eld splicing. (For existing TouchPad
connections and second port is added, select a location for the
second TouchPad installation that will be free from interference).
3. Determine which of the two TouchPads will use the TouchPad
Cover only and which will use the TouchCoupler unit as the pri-
mary connection.
Note: If TouchPad is not already installed, install TouchPad allowing
enough room for the TouchPad Cover to be securely placed over
the installed TouchPad.
4. Place the remote TouchPad Cover rmly over the Sensus Touch-
Pad until secured.
5. With the MXU door open, place the MXU over the second Touch-
Pad location and press rmly until unit is secured to the Touch-
Pad. For additional support (optional), pre-drill the holes
designed to fasten the unit to the wall. (Fastener holes are
located above the battery). Secure the unit to the wall with
screws.
Note: If not already installed, install the second TouchPad allowing
enough room to connect the MXU to the TouchPad.
Recommended Tools and Materials
Installation Instructions-Draft
Page 2 of 4
Sensus RadioRead
Model 510R2 Non Pit Unit
amr_321.fm Page 2 Tuesday, July 18, 2006 3:55 PM