26 Access Point Controller Card (APCC)
Installation Guide Sensys Networks, Inc.
Determining the Type of SPP Radio Bulkhead Connector
The bulkhead connector mechanism used on SPPs from Sensys Networks is one
type:
Hex-head type
Refer to the following figure to determine the proper installation procedure.
SPP Radio Bulkhead Connector
Figure 6.4. SPP radio bulkhead connector type: hex-head
Figure 6.4 shows the SPP hex-head connector. Follow the procedures in the
section
Connecting the Cable to an SPP Radio with the Hex-head Connector to connect the
Ethernet cable to SPPs using this connector type.
Connecting the Cable to an SPP Radio with the Hex-head
Connector
Follow the steps in this section to properly connect the cable to the SPP via the
hex-head bulkhead connector.
Components
Open the bulkhead connector kit and arrange the components as shown in the
following figure. In the figure, the two principal connectors are labeled A and B
respectively.
N
OTE
:
Two cable bushings are included; choose one to fit the outside diameter of the Ethernet
cable being connected to the SPP. Additionally, a spare gasket is included; use the gasket
only if the factory installed gasket is lost or visibly damaged.