Improper Fit (bushing poorly seated into guides)
Figure 6.19. Improper fit of cable bushing into connector B
10. Thread Connector A onto Connector B and tighten by hand until it no longer
turns easily.
N
OTE
:
Snug Connector A down by hand. Do not over-tighten or use tools.
Figure 6.20. Thread connector A onto connector B and hand tighten
11. Inspect the seating of the bushing by looking at it from the exposed cable end
of Connector A. Proper fit is achieved when all of the following conditions are
met:
bushing edge is recessed 1/8” to 1/4” below the lip of Connector A
bushing face is smooth - not puckered or pinched
bushing face does not protrude out of Connector A