Installation Guide

Table Of Contents
Configuration
Access Point Controller Card (APCC) 43
Sensys Networks, Inc. Installation Guide
Figure 7.9. Controller Card Channels tab
Configuring Channel State
Contact closure card channels are independent of one another and are individually
configured. Each channel occupies one of the following states:
Enabled the channel is operational; Sensor event data collected by the access
point is transmitted to the contact closure card.
Disabled – the channel is not operational. (When a channel is disabled, its
contact closure relay and status relay are continuously open.)
The factory default configuration enable channels one and two. Ensure that any
unused or unavailable channels are disabled.
Configuring Channel Mode
Enabled channels operate in one of the following modes:
Pulse – the contact closure relay pulses for 0.125 seconds each time the leading
edge of a vehicle is detected.
Presence – the contact closure relay remains closed while a vehicle is detected.
The factory default setting is pulse mode.