User's Manual

1608 4th Street Suite 200 Berkeley CA 94710
|
www.sensysnetworks.com/resources
|
P 510.548.4620 F 510.548.8264
Congure Repeater
Select a repeater from the image map
to access the Repeater Conguration
window with the Info tab open. The
Name eld allows the repeater’s name
to be user-dened.
Note: Repeater’s rmware version is for
reference only.
Repeater Conguration Window
3
Select an upstream channel by clicking
the Cong tab. Select an entry for the
Current Upstream Ch eld by clicking on
the Change to drop-down list.
Specifying Upstream Channel
Select a entry for the Current
Downstream Ch eld by clicking the
Change to drop-down list.
Specifying Downstream Channel
The default radio channel for access
point to repeater communications is 4.
The default radio channel for repeater to
sensor communications is 5.
Never use the same channel for
both access point and sensor
communications.
Refer to Sensys Network VDS240 Wireless
Vehicle Detection System TracDOT Set Up
and Operating Guide for more information.
Channel Notes
When an installation contains multiple
repeaters with more than 20 sensors,
changing one or more repeaters from
Current Cong 0 to Current Cong 1
allows the access point to communicate
with up to 40 sensors through the
repeaters.
Refer to Sensys Network VDS240 Wireless
Vehicle Detection System TracDOT Set Up
and Operating Guide for more information.
Cong Notes
Quick Start Guide: FlexNode Line Powered Radio (NA)