USER MANUAL USA VERSION GSM Door / Gate Intercom Entry System For Single Unit GSM‐DE3100 Speaker Microphone Call Button Optional Accessories: See page 17 DE-H1 Outdoor Housing DE-H2 Outdoor Housing with Access Control Keypad DE-H2 Outdoor Housing with Camera Please read this user manual and the quick setup guide completely and keep it for your future reference. MADE IN TAIWAN 4 BAND GSM WIRELESS MODULE MADE IN GERMANY IP65 Copyright © 2012 by Sentry US. All Rights Reserved.
Disposal of Old Electrical & Electronic Equipment (Applicable in the European Union and other European countries with separate collection systems). This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.
INDEX CAUTION ................................................................................................................................................................ 2 FRONT PAGE OF QUICK SETUP GUIDE ..................................................................................................................... 4 PACKAGE CONTENTS .............................................................................................................................................. 5 INTRODUCTION ........
See page 13 for enlarged screen capture pictures 4
PACKAGE CONTENTS 1) 2) Panel – Front 5) Panel – Rear with Plastic Back Cover 6) Power Adapter 12V DC 1.5A Two (2) Security Screws & Locking Washer Stainless Steel Surface Mount Panel Housing 7) Allen Wrench for Security Screws 3) 4) GSM External Antenna (9.8ft/3m lead) with Bracket 8) 3M Sticker + One (1) Screw & Wall Anchor for Antenna Bracket 9) User Manual Quick Setup Guide For any returns, please include all components listed above with original packaging in Resalable Condition.
(ITEM 17 on page 14) may be adjusted from 10 seconds to 99 seconds to adjust for different GSM service providers for voicemail answering. To register for one Admin only (11, 12, 13), set Ring Divert Time to 99 seconds. It is important to know that each Admin can dial program the system but only one (1) of the Admins (11, 12, 13) can register admins, users, and change system settings via SMS. This person with SMS capability is referred to as the Power Admin.
INSTALLATION SIM CARD INSTALLATION STEP 1. Face the panel so the SIM card tray is on the bottom left corner. Slide SIM card tray door left to unlock the tray. STEP 2. Flip up SIM card tray door. STEP 3. Insert SIM card into tray door with notched side of SIM card facing up and metal contacts on SIM card facing left. STEP 4. Gently push down to close tray door and pay careful attention to notch of SIM card. STEP 5. Slide tray door to the right in order to lock SIM card into place.
SYSTEM INSTALLATION The system can be installed either on a surface (Fig. 2) or recessed (Fig. 4). ADVISORY: 9 Light gauge is recommended (22ga stranded) for wiring unit’s open command. 9 Seal unit with silicone sealant paying careful attention to metal housing. Do not use silicon sealant on plastic housing or cover. 9 Be very careful with antenna when installing cover. 9 Tape antenna connections with electrical tape. 9 Do not pinch antenna cable when installing cover. 9 Do not use near sprinkler system.
WIRING LOCKS Depending on lock installed, the power can be sourced from the existing 12V DC 1.5A power supply or supplied separately using external power supply. Please be advised when sourcing power from door system, it should match required voltage with lock being installed. It is advised to install a separate external power supply for locks. WIRING LOCKS USING “SYSTEM” POWER SUPPLY WIRING LOCKS USING “EXTERNAL” POWER SUPPLY For Battery Backup recommendation, see page 17‐18 or visit www.sentryus.
LED INDICATORS LED Status Indicator Red Flashing = Standby Red Solid = Using LED Network Indicator Red flashes once per 3 seconds = Ready Red flashes once per second = Searching Red Solid = Busy LED Power Indicator Red Solid = Power On Red Off = Power Off ADDING ADMINS & USERS ADDING ADMINS The system has the ability to store one (1) Power Admin and three (3) Admins, where the Power Admin is an upgraded status for SMS programming and confirmation.
To add User 20, enter: To add User 100, enter: 12 12 1234 # 72 20 1phonenumber # 1234 # 72 100 1phonenumber # To delete a User, enter: To delete all Users, enter: 12 12 1234 # 73 usernumber 1phonenumber # 1234 # 73 # Example 3: An Admin wants to program User 2 into the system. His phone number is 999‐888‐4321.
REMOTE UNLOCK The default Relay Hold & Release Code is 5678. 1) Use your cell phone to dial into the system by entering the phone number of the SIM Card installed in the system. The system will then verify your phone number with the predefined numbers. You will hear a long tone when the door system answers the call. 2) To have Admin Call in to Unlock: 33 Momentary (Trigger Relay), enter: Admin can call into the system to unlock the door only once.
To check Minutes/Balance Status on SIM Card, enter: Feature may not work in United States. 23 # To Add Check Balance Code, enter: 78 xxxxxxx # Enter code for SMS check balance from service provider (related to check minutes/balance status on SIM card). *Must change to Check Balance Code of Service Provider. For a chart of the important programming key codes, see page 14.
Copyright © 2012 by Sentry US.
SPECIFICATIONS Model Operating Voltage Operating Current GSM Frequency / Module Protection Humidity Operating Temperature Faceplate Dimension (L x W x H) Module Housing Dimension (L x W x H) GSM‐DE3100 12V DC or 24V AC (includes 12V DC 1.5A Power Adapter) Under 12V DC: 55mA Standby, 250mA max GSM 850/900/1800/1900 Wireless Module Made in Germany by Cinterion IP65 Less than 80% RH ‐4°F ~ 122°F / ‐20°C ~ 50°C 6.69” x 3.94” / 170mm x 100mm 6.85” x 4.44” x 2.56” / 174mm x 113mm x 65mm 1.14” x 0.
OPTIONAL ACCESSORIES Outdoor Housing Option 2 DE‐H2 (for use with Access Control Keypad or Camera) Outdoor Housing Option 1 DE‐H1 Example: Examples: Accessories for using GSM‐DE3100 system with DE‐H2 housing: Analog Pinhole Camera * Wireless 3G Camera coming soon! Stand‐Alone Access Control Keypad with Built‐in EM Reader ** ACSK‐EM RFID EM Keyfob ** ACC‐EMTAG‐B Proximity Clamshell ID Access Card ** ACC‐EMC ** Only to be used with Access Control Keypad Battery Backup System MD‐E‐KIT Kit Includes:
RELATED PRODUCTS Video Intercom System Security Alert System ‐ Relay and Module 16.5V AC 1.5A Battery Power Charger MD‐BPC612 24V AC 7A Battery Power Charger MD‐BPC61224 High Voltage Relay MD‐HVR 4 Channel Recordable Siren & Voice Annunciator Module MD‐SVOICE4 8 Channel Recordable Voice Annunciator Module MD‐VOICE8 365 Days Schedule Timer MD‐T365 www.SentryUS.com Additional Technology Security Inc. dba: Sentry US 5500 Stewart Avenue Fremont, CA 94538 E‐mail: info@SentryUS.