MultiPoint Level Control System Customer Product Manual Part 321 351A NORDSON CORPORATION D DULUTH, GEORGIA D USA www.nordson.
Nordson Corporation welcomes requests for information, comments and inquiries about its products. General information about Nordson can be found on the Internet using the following address: http://www.nordson.com. Address all correspondence to: Nordson Corporation Attn: Customer Service 11475 Lakefield Drive Duluth, GA 30097 Notice This is a Nordson Corporation publication which is protected by copyright. Original copyright date 2001.
Table of Contents i Table of Contents 1. Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safety Alert Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Responsibilities of the Equipment Owner . . . . . . . . . . . . . . . . . . . . . 2 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Instructions, Requirements, and Standards . . . . . . . . . . . . . . . .
ii Table of Contents 3. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Connecting the Feeding Unit to the H20 Gun . . . . . . . . . . . . . . . . 16 Connecting the Feeding Unit Without a Gun . . . . . . . . . . . . . . . . . 16 Connecting the H20 Gun to the Lid Kit/Applicator Unit . . . . . . . . . 16 Mounting the Level Control Cabinet . . . . . . . . . . . . . . . . . . . . . . . . 17 Wiring Instructions . . . . . . . . . . . . . . . . . . .
MultiPoint Level Control System 1 MultiPoint Level Control System 1. Safety Read this section before using the equipment. This section contains recommendations and practices applicable to the safe installation, operation, and maintenance (hereafter referred to as ”use”) of the product described in this document (hereafter referred to as “equipment”). Additional safety information, in the form of task-specific safety alert messages, appears as appropriate throughout this document.
2 MultiPoint Level Control System Responsibilities of the Equipment Owner Equipment owners are responsible for managing safety information, ensuring that all instructions and regulatory requirements for use of the equipment are met, and qualifying all potential users.
MultiPoint Level Control System 3 User Qualifications Equipment owners are responsible for ensuring that users: S Receive safety training appropriate to their job function as directed by governing regulations and best industry practices. S Are familiar with the equipment owner’s safety and accident prevention policies and procedures. S Receive, equipment- and task-specific training from another qualified individual.
4 MultiPoint Level Control System Instructions and Safety Messages (contd) S Read and follow the instructions provided in this document and other referenced documents. S Familiarize yourself with the location and meaning of the safety warning labels and tags affixed to the equipment. Refer to Safety Labels in this section. S If you are unsure of how to use the equipment, contact your Nordson representative for assistance.
MultiPoint Level Control System 5 Operating Practices S Familiarize yourself with the location and operation of all safety devices and indicators. S Confirm that the equipment, including all safety devices (guards, interlocks, etc.), is in good working order and that the required environmental conditions exist. S Use the personal protective equipment (PPE) specified for each task. Refer to Equipment Safety Information or the material manufacturer’s instructions and MSDS for PPE requirements.
6 MultiPoint Level Control System Equipment Safety Information This part provides safety information applicable to the following types of Nordson equipment: S hot melt and cold adhesive application equipment, including melters, hoses, and guns. S auxiliary equipment, including pattern-controllers, timers, and other similar devices. Equipment Shutdown To safely complete many of the procedures described in this document, the user must first shut down the equipment.
MultiPoint Level Control System 7 Disable the Gun All electrical or mechanical devices that provide an activation signal to the gun solenoid(s) or the melter pump must be disabled before work can be performed on or around a gun that is connected to a pressurized system. 1. Turn off or disconnect the gun triggering device (pattern controller, timer, PLC, etc.) 2. Disconnect the input signal wiring to the gun solenoid valve(s). 3.
8 MultiPoint Level Control System General Safety Warnings and Cautions (contd) WARNING: System pressurized! Relieve system hydraulic pressure before breaking any hydraulic connection or seal. Failure to relieve the system hydraulic pressure can result in the uncontrolled release of hot melt that can cause personal injury. WARNING: Molten Material! Wear eye or face protection, clothing that protects exposed skin, and heat-protective gloves when servicing equipment that contains molten hot melt.
MultiPoint Level Control System 9 WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use of untrained or inexperienced personnel to operate or service the equipment can result in injury, including death, to themselves and others, and damage to the equipment. CAUTION: Hot surfaces! Avoid contact with the hot metal surfaces of guns, hoses, and certain components of the melter.
10 MultiPoint Level Control System Other Safety Precautions S Do not use an open flame to heat hot melt system components. S Check high pressure hoses daily for signs of excessive wear or damage. S Never point a dispensing handgun at yourself or others. S Suspend dispensing handguns by their proper suspension point. First Aid If molten hot melt comes in contact with your skin: 1. Do NOT attempt to remove the molten hot melt from your skin. 2.
11 MultiPoint Level Control System 2. System Overview System Description The MultiPoint Level Controller automatically senses the adhesive level in the applicator’s tank, thereby eliminating the need for an operator to manually fill each unit. The Controller is responsible for refill, shutoff, and alarm functions. See Figure 1. The MultiPoint Level Control System consists of the Control Box, the RIA 450 Level Controller, the MultiCap Probe and the Lid Kit.
12 MultiPoint Level Control System The level control process starts when a low voltage, high frequency signal is sensed and sent to the capacitance MultiCap Probe then to the ground plane. The control relay is calibrated to ignore this signal unless hot material contacts the MultiCap Probe. If hot melt material contacts the MultiCap Probe, additional current flows to the ground, is sensed, and amplified by the control relay. Internal circuitry reads this amplified signal and regulates the filling process.
13 MultiPoint Level Control System Control Box The Control Box is used as the connecting unit for the Endres+Hauser RIA 450 Controller, MultiCap Probe, lid kit, and optionally an automatic gun. All operator controls and indicators are located on the control box front panel. See Figure 3, Front View of Controller. 12 11 10 MANUAL 1 AUTO OFF MAN 9 OVER 8 NORMAL AUTO SILENCE ON 7 UNDER OFF 6 5 4 2, 3 6901002A Fig. 3 1. 2. 3. 4.
14 MultiPoint Level Control System RIA 450 Controller WARNING: Warning on RIA 450 Level Controller: Disconnect power before opening cabinet ground equipment. Failure to follow these instructions may result in death. The Endres+Hauser RIA 450 Controller is a subassembly of the Control Box. The Controller has four user programmable setpoints and each setpoint has a user programmable hysteresis. The Controller is responsible for refill, shutoff, and alarm functions as follows.
15 MultiPoint Level Control System MultiCap Probe The MultiCap Probe contains an FEC 12 electronic insert that functions as a transmitter for capacitance measurement. Capacitance measurement functions: S The MultiCap Probe and vessel form a capacitor. S Depending on the level, the space between these capacitor plates is filled either with air (empty vessel) or an unspecified quantity of material.
16 MultiPoint Level Control System 3. Installation This section contains the installation procedures necessary to install the MultiPoint Level Control System for various applicators. Inventory and inspect the MultiPoint Level Control System components. The gun, solenoid, and filter/regulator are ordered and shipped separately. WARNING: Warning on RIA 450 Level Controller: Disconnect power before opening cabinet ground equipment. Failure to follow these instructions may result in death. 1.
MultiPoint Level Control System Mounting the Level Control Cabinet 17 1. Mount the level control cabinet in a location as far away as possible from vibration, corrosive atmosphere and potential mechanical damage. NOTE: in order to prevent signal drop-off, it is recommended that the level control cabinet be located as close as possible to the filling cabinet. (This instruction applies to the distance between the feed unit and the level control box). Wiring Instructions 1.
18 MultiPoint Level Control System Wiring Instructions (contd) 5. Route a 1-phase, 120 VAC input power supply line through the strain relief and connect it to terminals XT1-1 and XT1-2 inside the level control cabinet. 6. Connect the input power supply line ground wire to XT1-3 inside the level control cabinet. 7. Refer to feed unit manual and applicator manuals for specific setups. 4. System Setup Verifying Program Values Fig. 6 The RIA 450 Level Controller is pre-programmed prior to shipping.
19 MultiPoint Level Control System Resetting Program Values 1 2 3 6901015A 1. Use the programming buttons Minus (1), Plus (2), and Enter (3) to reset the RIA 450 Level Controller to recommended settings. 2. Press and hold the ENTER button (E) to display the operating matrix table. 3. Press the ENTER button (E) to move across the table. 4. Press the minus (–) or plus (+) button to change the settings in the display and move up or down the table. 5. Press ENTER to retain the settings. 5.
20 MultiPoint Level Control System Activating the Control System (contd) 22 5 24 25 1 2 19 27 26 20, 23 AUTO 14 G 13 12 11 10 9 MANUAL 14 G 13 12 11 10 9 18 21, 22 14 G 13 12 11 10 9 OFF 28 MAN AUTO OVER 8 4 7 3 6 2 5 1 8 4 7 3 6 2 5 1 8 4 7 3 6 2 5 1 9 NORMAL SILENCE ON UNDER 29 OFF 8 30 7 3, 4 6 14, 15 12, 13 16, 17 10, 11 6901010A Fig. 7 Control Box 1. Level RIA 450 Level Controller Enclosure 2. Panel Enclosure 3. Switch 4. Manual, Auto, Off Legend 5.
MultiPoint Level Control System Operating Modes 21 The level control may be set for any of three modes: S OFF: The RIA 450 Level Controller does not function. S AUTO: The RIA 450 Level Controller circuitry activates the pump/automatic gun when the level of material in the tank/hopper reaches the REFILL START setpoint and deactivates the pump/automatic gun when the level reaches the REFILL SHUTOFF setpoint. An alarm sounds when a high or low alarm setpoint is reached.
22 MultiPoint Level Control System High Level (contd) The equipment operator must: S Press the Horn SILENCE button to deactivate the alarm. S Stop the fill process that caused the overfilling and lower the amount of material in the tank/hopper to the Refill Start Setpoint (the OVER lamp goes off, the NORMAL lamp goes on and the RIA 450 Level Controller will activate the pump/automatic gun as required.
MultiPoint Level Control System Calibration 23 MultiCap Probe/FEC 12 Electronic Insert Calibration Procedures Calibration is carried out at the FEC 12 Electronic Insert by using four pushbuttons. (See Figure 8). 1. Press the two push buttons on the left of the MultiCap Probe simultaneously (6) when the material is just touching the bottom of MultiCap Probe to set low point. 2. Press and hold the 2 push buttons (6) until LED illuminates (5). 3.
24 MultiPoint Level Control System 7.
XT1–1 3 1 L1 50 F1 (1 AMP) 70 13 PE 13 81 11 60 (J1) GND4 LEVEL CONTROL RIA 450 N/L– L/L+ SW 40 IN COMING POWER 120 VAC GND1 P1 P2 XT1–9 (TO PROBE) XT1–10 4 2 XT1–2 N 60 XT1–3 70 70 70 70 70 70 70 70 70 70 XT1–4 52 53 RIA 450 45 46 RIA 450 43 42 RIA 450 5 CR150 7 7 6 CR150 CR180 11 7 1 3 1 3 1 2 4 2 4 2 200 210 210 291 251 150 170 180 10 CR180 2 4 12 CR230 2 SW230 1 SILENCE 12 CR170 8 300 300 XT1–5 280 270 CR230 210 7 11 SW250 OFF MAN.
26 MultiPoint Level Control System This page left intentionally blank.
27 MultiPoint Level Control System 8. Parts To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use the parts list, and the accompanying illustration, to describe and locate parts correctly. Using the Illustrated Parts List Numbers in the Item column correspond to numbers that identify parts in illustrations following each parts list. The code NS (not shown) indicates that a listed part is not illustrated.
28 MultiPoint Level Control System Level Control Components Item See Figure 11.
MultiPoint Level Control System 22 5 1 24 25 29 2 19 27 26 20 AUTO 4 3 4 7 8 23 14 G 13 12 11 10 9 MANUAL 14 G 13 12 11 10 9 18 14 G 13 12 11 10 9 OFF 28 MAN AUTO 21 OVER 6 2 1 5 8 3 7 6 2 1 5 3 4 7 8 6 2 1 5 9 22 NORMAL SILENCE ON UNDER 29 OFF 8 30 7 3 4 6 14 16 15 17 12 10 13 11 6901008A Fig.
30 MultiPoint Level Control System Level Control Mounting Hardware Kit Parts List (for FM-151 Applicator) Lid Kit for FM 151 Item Part Description Quantity 809786 Kit H/W, Mounting, Level Control, FM-151 Version 1 981906 Screw, Socket Head Cap, 1/4-20 x 0.75 in. (Kit P/N 809786) 8 2 983140 Lockwasher, Split, 0.25 in.
31 MultiPoint Level Control System Level Control Mounting Hardware Kit Parts List (FM-190 Applicator) Lid Kit for FM-190 Item Part Description 100787 Kit Mounting E-H Level Control, FM-190 1 100789 Cover, Hopper (Kit P/N 100 787) 2 1/ 1 Screw, Fillister Head, 3 983140 Lock Washer, Split, 1/ 4 972055 Connector, Male 1 5 972622 Connector, Male, 37” 11/16-12 x 3/8 NPT 1 6 803068 Adapter, Slot Nozzle, H2O 1 2 2 4 7 973979 Adapter, SAE, 8 241889 Lid, Loading 1 9 981737
32 MultiPoint Level Control System 69–LVL–EH–IS–01 321 351A Issued 7/01 E 2001 Nordson Corporation All rights reserved