Instruction Manual

INSTALLATION INSTRUCTIONS
senvainc.com 1-866-660-8864 (F)1-503-296-2529 9290 SW Nimbus Ave. Beaverton Oregon 97008
Indoor Air Quality Sensor
BACnet/Modbus/Analog
PRODUCT IDENTIFICATION
AQ2 -
VOC
CO2
Pkg RHOut
Package
W = Surface
Output Type
A = 3-wire Analog
B = BACnet/Modbus
Temperature Output
A = None
B = Transmitter and display/comms temp reading
C = 100Pt RTD
D = 1000Pt RTD
E = 10K Type 2
F = 10K Type 3
G = 10k w/11k
H = 3k
I = 2k2
J = 1k8
K = 20k
CO2
A = None
C = Standard CO
D = Dual Channel CO
Relative Humidity
A = None
2 = 2% RH accuracy
PM
VOC
A = None
V = TVOC
Particulate Matter
A = None
P = PM 1.0, 2.5, 4.0, 10.0 (Available on AQ2W-B
BACnet/Modbus versions only)
Display
X = None
D = Color OLED Display
S = Color OLED display with solid cover
R = Air Quality Ring
T
Disp
PIR Motion/Occupancy Sensor
Blank = None
P = PIR Sensing
IMPORTANT WARNINGS
Only qualied trade installers should install this product
This product is not intended for life-safety applications
Do not install in hazardous or classied locations
The installer is responsible for all applicable codes
De-energize power supply prior to installation or service
PRODUCT APPLICATION LIMITATION:
Senva products are not designed for life or safety applications. Senva products
are not intended for use in critical applications such as nuclear facilities, human
implantable device or life support. Senva is not liable, in whole or in part, for
any claims or damages arising from such uses.
FEATURES
The TotalSense series design allows customization for a sensor
that meets project requirements for monitoring temperature,
carbon dioxide (CO), total volatile organic compounds
(TVOC), particulate matter (PM), relative humidity (RH),
passive-infrared occupancy sensor (PIR), and ambient light.
The product can be ordered as a stand-alone CO, RH, Temp,
TVOC, PM, or PIR sensor as well as almost any combination of
sensors. Resistive-set-point sliders and pushbuttons are also
available to meet the requirements for any job. All models
come standard with programmable set-point relay (except on
PM models) and barometric pressure compensation for CO.
Choose the analog version to receive up to three
selectable and programmable analog outputs or utilize the
communications version to access a myriad of data through
Modbus RTU or BACnet MS/TP. Communications version
comes standard with ambient light sensing.
To verify the features see the
'Product Identication section of
the installation manual or use the
conguration tool at senvainc.com or
scan the QR code on the right.
TotalSense Congurator
Accessories
† ‡
C = 1k  Setpoint Slider
D = 10k  Setpoint Slider
T = 200-900  Setpoint Slider
E = 910  oset resistor (available with slider only)
S= Slider override Pushbutton (available with slider only)
O = Thermistor Override Pushbutton
U = User Pushbutton
Additional Setpoint sliders and oset resistors available
upon request
‡ Slider and pushbutton options not available with PM sensor
Acc
T talSense