User's Manual

MOD-10-1164
sepura
TETRA Terminals
Product Guide
29/8/2012
Page 9 of 45
Issue 10
© Sepura plc 2012
OPERATIONAL REQUIREMENTS
All features and functions of Sepura radios are subject to network support of the
TETRA Interoperability Specifications.
OPERATING CONDITIONS
Sepura radios operate in a temperature range between -20ºC and 60ºC and a maximum
humidity of 98%. They may be safely stored at a temperature within the range -40ºC to 85ºC.
The minimum and maximum temperatures for operation are -30°C to +70°C.
However operating at temperature extremes may limit some aspects of operational
performance.
IP, IEC AND ATEX RATINGS
The Sepura radios are certified to the following IEC529 IP, Global IEC and European ATEX
standards:
Product
IP
Standard
IEC Standard
European ATEX Standard
STP8X
IP67
IEC 60079-0 and IEC 60079-11
EN 60079-0 and EN 60079-11.
STP8000,
STP8100
IP55
STP8200
IP54
SRH3500,
SRH3800,
SRH3900
IP54
SRG3500,
SRG3900
IP54
The STP8000, STP8100, STP8200 and STP8X radios have been tested for a full 8
hour shift in IP54 conditions. This is equivalent to 8 hours of constant rain.
The SRH3900 radio has been tested in IP54 conditions equivalent to 2 hours of driving
rain.