User's Guide

SETUP AND TROUBLESHOOTING
SETUP DETAILS
9 PROPRIETARY GM01Q-STMOD TEST KIT USER MANUAL
SEQUANS Communications
3.1.2 Control the Installation
After completing the drivers' installation, whenever you plug the USB cable
you should be able to see the following, under Windows Control Panel ->
Device Manager.
Figure 3-2: Device Manager after Driver Install
Note: Port enumeration can be different on your PC from the given
example, depending on your local settings.
3.1.3 Setting of the COM Ports
Table 3-1 summarizes the COM ports under Windows and their mapping and
configuration to the Test Kit.
Note: COM ports cannot be shared between two different applications
in the same time. One of the applications will be in error.
Table 3-1: COM Ports Setting
Port Enum
Sequans
Mapping
Usage Baudrate Data Bits
Flow
Control
Parity Stop
COMa (here COM16) Serial2 AT Command
Data over PPP
921600 8 Hardware None 1
COMb (here COM15) Serial1 Test Kit Console 115200 8 None None 1
Rev4 Draft