Data Sheet

PHYSICAL CHARACTERISTICS
COMPONENT RELIABILITY
SP150Q DATASHEET PROPRIETARY 26
SEQUANS Communications
Table 3-13: SP150Q ESD Test Conditions (IEC 61000-4-2 Standard)
Test Parameter Description
Discharge Voltage Direct Discharge Air 8 kV
Contact 4 kV
Indirect Discharge HCP 4 kV
VCP 4 kV
Polarity Positive / Negative
Discharge Impedance 330 Ohm
Discharge Capacitance 150 pF
Number of Discharge Minimum 10 times at all test point for Air condition.
Minimum 25 times at all test point for Contact condition.
Minimum 25 times at all test point for HCP/VCP condition.
Discharge Mode 1 time per second
Table 3-14: Description of Criterium of ESD Test
Criterion Description
A The equipment shall continue to operate as intended without operator intervention. No degradation
of performance or loss of function is allowed below a performance level specified by the
manufacturer when the equipment is used as intended. The performance level may be replaced by a
permissible loss of performance. If the minimum performance level or the permissible performance
loss is not specified by the manufacturer, then either of these may be derived from the product
description and documentation, and by what the user may reasonably expect from the equipment if
used as intended.
Table 3-15: ESD (Indirect Discharge) Test Results
Test Level (kV) Polarity (+/-) Test Point HCP Result VCP Result
4 kV +/- 4 sides A A