User's Manual

Appendix C RF cable loss values for lab
testing
The DUTs prepared for the certification have been calibrated at the M2 antenna port, hence the new
small grey cable which is not seen, as the samples have been closed need to be added as extra loss.
This cable is identified as Digikey 931-1193-ND
Please see below the datasheet, which shows a graph of the insertion loss of the cable.
Cable loss values
To ease process, please use the table below, either R&S platform or Anritsu platform is being used for
testing.
Frequency(GHz)
Cable Loss(dB)
0.00
0.00
0.10
0.10
0.30
0.20
0.50
0.39
0.75
0.38
0.78
0.36
1.71
0.55
1.76
0.55
2.11
0.61
2.16
0.61
3.00
0.83
3.10
0.74
Cable datasheet
The datasheet of the cables is available
under http://taoglas.com/images/product_images/original_images/CAB.S01.pdf
Insertion loss data extract below