User's Manual

3
Every group can be support to associated 5 devices max.
GROUP 1 is lifeline service that assigned to Sensor (Motion detector) status Open/Close. It enables the sensor to send reports
and readings to a Z-Wave Controller or Z-Wave Gateway whenever the sensor is triggered. This Group Support:
NOTIFICATION_REPORT_V4
DEVICE_RESET_LOCALLY_NOTIFICATION
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
BATTERY_REPORT
GROUP 2 allows for Sending Basic to associated devices in this group. This Group Support:
BASIC_SET
Reset to Factory Defaults
1. Press the tamper switch 4 times within 2 seconds and hold the 4
th
press until the PIR LED lights up.
2. The PIR LED will be off after 3 seconds and all settings will be reset to factory defaults.
Walk Test
1. The PIR will be in Walk Test mode for 3 minutes after install the battery. After 3 minutes, the PIR will return to normal
operation mode if the Walk Test jumper is not installed.
2. If the installer needs longer time to perform walk test, install the Walk Test jumper and the PIR will NOT return to normal
operation mode.
3. Rearm timer is configured to 2 seconds for walk test and 3 minutes for normal operation mode.
4. To save the battery, remember to remove the jumper after walk test finished.