User's Manual

6
Z-Wave Command Classes
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_VERSION
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_BATTERY
COMMAND_CLASS_NOTIFICATION
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_BASIC
COMMAND_CLASS_WAKE_UP
COMMAND_CLASS_FIRMWARE_UPDATE_MD
COMMAND_CLASS_SENSOR_MULTILEVEL
COMMAND_CLASS_CONFIGURATION
Z-Wave Configuration
Configuration
Parameter
Function
Size
(Byte)
Unit
Default
Setting
Description
1
Configure motion
trigger interval
2
1s
180s
After motion detected, ignores
consequent motion events during
the trigger interval to save battery
power.
If Walk Test jumper is
enabled, the interval will be set to
2 seconds and ignores this
configuration.
Notification Type
Switch Type
Status
Notification Type
PIR ON/OFF
0x07
Tamper Switch
0x07
Event
PIR ON/OFF
Close:0x00, Open:0x08
Tamper Switch
Close:0x00, Open:0x03
BASIC Report
PIR ON/OFF
Close:0x00, Open:0xFF
Alarm V1
(Movement)
Alarm Type
0x07
Alarm Level
0x00 (No movement after3
mins )
0xFF (Motion detected)