Join Function
For "Join" a network, please do the following instruction:
Press the Join/Leave button for less than 1 second. The LED is blinking while
processing. If the sensor has been joined with the controller successfully, the Green
LED will be on for 2 seconds and then off. The Green LED will be off instantly if failed.
Leave Function
For "Leave" a network, please do the following instruction:
Press Join/Leave button for 3 seconds to let the sensor disassociate from the controller.
The LED will stay off during the normal operation.
The sensor is equipped with a tamper switch. If the cover of sensor is removed, the sensor
will send an alarm to the ZigBee controller. The sensor will be in "Awake" mode before
replacing
External contact wiring (Optional)
1.remove screw
2.Plug two-pin connector.
3.close screw
4. Connect wire to N/C dry reed switch device. (Option)