Specifications

Adjustments to be made regularly
Adjustment of the MIN and MAX value
Adjustment
of
the
HIGH T STOP and LOW T STOP
value
The MIN and MAX value is the lowest respectively highest value that is allowed for the supply line
temperature. Adjusting the minimum and maximum supply line temperature is particularly important if
your home has floor heating. If your house has floor heating and parquet floor, the supply line
temperature should not be higher than 45°C. Else the floor might get damaged. If you have floor coils
and stone tiles, the MIN value should be 22-25°C in summer when no heating is required to obtain a
comfortable floor temperature.
MIN is the minimum setting of feed water temperature; it is adjustable by operator from10 to 30 ć,
factory setting is 22ć; if the room’s floor use ceramic tile, then the setting of MIN can not less than
22ć (this value can get a comfortable floor temperature); the heat pump will restart as soon as
actual feed water temperature less than MIN setting.
MAX is the maximum setting of feed water temperature, it is adjustable by operator from 30 to 70ć,
and factory setting is 70ć; if heat pump is using for floor heating, this setting is very important,
because at the time the feed water temperature can not higher than 70ć, otherwise could be
dangerous; the heat pump will stop as soon as actual feed water temperature more than MAX
setting.
1. Open the main menu INFORMATION by pressing the right- or left-hand button once. You will find the
cursor at the sub-menu OPERATION
2. Press the ”down” button to move the cursor to the sub-menu HEAT CURVE
3. Open the selected menu by pressing the right-hand button once. You will find the cursor at the
parameter CURVE.
4. Press the ”down” button to move the cursor to MIN.
5. Open the selected parameter by pressing the right-hand button once. The cursor is at MIN
6. Raise or lower the value, using the ”up” and ”down” button respectively.
7. Press the left-hand button three times to return to the main menu.
Repeat the procedure to change the MAX value, replacing MIN by MAX at step 4.
If there is a basement to your house, the MIN value should be adjusted to a suitable temperature in
summer too, to avoid a humid and chilly basement. In such cases, the value for HEAT STOP needs
being adjusted upwards. If you wish to change the MIN or MAX value:
is
equal
to
higher or lower
than
the
value
enter
ed
for
HIGH T STOP or LOW T STOP.
When
the
function
is
activated,
the
cir
culation
pump
will
be
turned
of
f. The factory setting of the HIGH T STOP is 50°C.( 0 ~ 50 °C adjustable )
If
you
wish
to
change
the
HIGH T STOP OR LOW T STOP
value:
1
Open
the
main
menu
INFORMA
TION
by
pr
essing
the
right-
or
left-hand
button once.
Y
ou
will
find
the
cursor
at
the
sub-menu
OPERA
TION
2
Pr
ess
the
”down”
button
to
move
the
cursor
to
the
sub-menu
HEA
T
CURVE
3
Open
the
selected
menu
by
pr
essing
the
right-hand
button
once.
4
Y
ou
will
find
the
cursor
at
the
parameter
CURVE.
The factory setting of the LOW T STOP is -50°C.( -50 ~ 0 °C adjustable )
‘HIGH T STOP’ and ‘LOW T STOP’ functions are only for room heating, the water tank
normally when the two functions are active.
heating still works
The
HIGH T STOP and LOW T STOP
function
stops water production to room floor
when
the outside air
temperatur
e
Control37