Specifications

18Control
General information
Menu
Navigation
Display
of
curr
ent
operating
mode
The right-hand button on the control panel is used to open the desired menu.
The left-hand button is used to return to the previous menu.
The up and down buttons are used to navigate between the parameters of a menu.
A cursor (arrow) on the left-hand side of the display indicates which menu can be opened.
The up and down buttons are also used if you wish to increase or reduce a preset value.
During normal operation, the following information will be displayed:
• Desired (preset) room temperature
• Date / time / timer
heat pump or auxiliary heater or both (see ”Symbols”).
• Which operating mode has been selected.
• Whether there is a heating demand or not. If there is, there will
also be symbols telling which heat source is working,
When display at the interface, press button Right for 5 seconds for locking the display (will show a symbol
of lock.) All buttons are not available after lock is active, until press button Right for 5 seconds to open the lock˗
if the lock is active and then power supply cut off, the lock will be open after power supply resume.
Main
Menu
INFORMA
TION
T
o
open
the
main
menu
INFORMA
TION,
pr
ess
the
right-
or
left-hand
button
once.
T
o
select
the
desir
ed
sub-menu
use
the
up
or
down
button.
Open
the
menu
by
pr
essing
the
right-hand
button
once.
T
o
r
eturn
to
the
main
menu,
pr
ess
the
left-hand
button
once.
ROOM 20
MONDAY
11:30
1
HDO
CSP
95
%
OPER.WARMWATER
RESET
MAN TEST
INFORMATION
OPERATION
HEATCURVE
TEMPERATURE
INTEGRAL
TIMESETTING
SETTING
OPER.TIME
Return
Open
next
menu
Sub
menus
OPERATION
HEATCRVE
The setting of this submenu will affect the room temperature; CURVE is program that adjusts feed water
temperature according outdoor ambient temperature, factory setting is ambient temperature 0 as feed water
temperature 40ć, that is CURVE =40; the value of CURVE is adjustable from 22ć to 56ć. How to change
the slope—two points decide one beeline, point one is (0,40), the other point could be (18,24), the point
(18,24) is not changing when changing the slope, because factory setting is that heat pump stops when
outdoor ambient temperature is 18ć, so the feed water temperature should be 24ć.
TEMPERATURE
Temperature items setting.
Running mode: Water tank heating, Room heating, Room heating 1, Room heating 2,
Auto ;
LANGUAGE
ALARM RECORD