CSP-EZ (94160 /94150 ) User Manual

cone washer
valve cover
UNIT TROUBLESHOOTING
POSSIBLE PROBLEM:
Unit does not cool.
POSSIBLE SOLUTIONS:
Ensure cord is securely plugged in.
Verify that cord is securely plugged into the unit,
the power supply (adaptor), and the power source
(electrical outlet).
Ensure power is available from source.
Ensure unit is on.
Ensure fan is on/running.
Ensure lter is clean or replace if necessary.
VALVE COVER ASSEMBLY
a
INSTALL CONE WASHER INTO VALVE COVER.
b INSTALL VALVE COVER, WITH CONE WASHER
INSIDE, ONTO DISCHARGE TUBE THREADING.
c ROTATE VALVE COVER CLOCKWISE TO SECURE TO
THREADS OF DISCHARGE TUBE.
Do not use any sharp tools for assembly,
this can damage parts.
b
a
c
VALVE COVER ASSEMBLY
PUMP TROUBLESHOOTING
PROBLEMS WITH PUMP OPERATION AND/OR FLOW:
Clean pump.
PUMP DISPENSES LITTLE OR NO PRODUCT.
Product may be too stiff or contain a solid
that will not pass through pump.
PORTION CONTROL IS NOT CONSISTENT.
Inspect gaging collar for any damage and/
or proper installation.
PUMP PLUNGER DOES NOT RETURN TO TOP OF
STROKE AFTER DISPENSING PRODUCT.
Inspect spring for any damage; bent or
broken. Replace spring if necessary.
PUMP DRIPS.
Clean discharge tube with supplied
cleaning brushes.
Ensure product is not being heated by
any external source(s) causing product to
expand and drip from pump.
b
a
a