User guide
Virtual Connect fabrics  141 
•  The VC-FC and FlexFabric modules use dynamic login distribution to equally distribute server logins 
across all available uplink ports. The port with the least number of active logins is used for server 
connectivity. When the number of logins is equal, VC-FC or FlexFabric modules utilize a round-robin 
technique. 
•  The VC-FC and FlexFabric modules use dynamic login distribution to provide an uplink port failover 
path that enables server connections to fail over within the VC SAN fabric. If a VC SAN fabric uplink 
port becomes unavailable, servers logged in through that uplink are automatically reconnected using 
one of the remaining uplinks in the VC SAN fabric, resulting in automatic failover. 
•  When a previously failed uplink is reconnected to the fabric, no server logins on the VC-FC modules are 
moved to the newly available port. This can cause an unbalanced situation where some uplink ports 
have more server logins than others. When enabled for VC FlexFabric modules, Automatic Login 