User guide
Virtual Connect fabrics  149 
Task  Description 
Set the preferred or maximum FCoE 
connection speed 
After a FlexFabric module port has been added, select the Show 
Advanced Settings checkbox, click the selection box, and then select a 
setting (0.1Gb to 8 Gb): 
•
  Set Preferred FCoE Connection Speed—Applies to server profiles 
with an FCoE connection specified. Select a speed value for the 
FCoE connection and server port associated with this fabric. 
•
  Set Maximum FCoE Connection Speed—Applies to server profiles 
with an FCoE connection specified. This setting limits the maximum 
port speed from the server for the FCoE connection associated with 
this fabric. 
Delete an uplink port 
Left-click an uplink port row to select it, right-click to display a menu, and 
then select Delete Port, or click Delete in the Action column. 
Save changes 
Click Apply. 
Cancel without saving changes 
Click Cancel. 
Login re-distribution 
Login Re-Distribution 
When creating or editing a SAN fabric using HP VC FlexFabric 10Gb/24-port Modules in a FabricAttach 
fabric, select the Show Advanced Settings checkbox to select the login re-distribution: 
•  Manual Login Re-Distribution—Default for all FC modules. You must initiate a Login Re-Distribution 
request through the VC GUI or CLI interfaces. You might re-distribute logins if an uplink that was 
previously down is now available, if you added an uplink to a fabric, or if the number of logins through 
each available uplink has become unbalanced for any reason. 
•  Automatic Login Re-Distribution—When selected, the VC FlexFabric module initiates Login 
Re-Distribution automatically when the specified time interval expires. For more information about 
setting the time interval, see "Fibre Channel Settings (Misc.) screen (on page 156)" . 
The automatic option is only available on FlexFabric modules in a FabricAttach fabric and enables you to 
specify an interval, in seconds, for the length of time the previously offline links must be stable before the 
module can re-distribute logins. Login re-distribution is not supported for DirectAttach fabrics. 
FCoE Connection Speed 
To change these settings, click the selection box, and then select a setting (100Mb to 8Gb):  
•  Set a custom value for the Preferred FCoE Connection Speed. This value is the default speed for server 
profile connections mapped to this network. The server administrator can override this setting on an 
individual profile connection.   