User guide
Virtual Connect server profiles  164 
Because of the many possible configurations of the FlexFabric module, pluggable modules can differ for each 
uplink port on the FlexFabric module. If the uplink port is being used for an FC fabric, an SFP-FC connector 
is required. SFP speeds of 2Gb, 4Gb, or 8Gb are supported for this configuration. A 1G SFP connector is not 
supported on ports X1-X4 for either Ethernet or FC configurations. For Ethernet ports, the 10GbE SFP-LRM 
pluggable module is not supported on ports X1-X4. The Ethernet SFP-LR and SFP-SR are supported on all 
ports. 
In a multi-enclosure environment, all enclosures must have the same VC-FC and FlexFabric module 
configuration. For example, if the local enclosure has VC-FC modules in bays 3 and 4, each remote 
enclosure must also have VC-FC modules in bays 3 and 4. This is called an FC bay group. Support for FC bay 
groups with FlexFabric modules is similar to support for existing VC-FC modules. FlexFabric module bay 
groups cannot contain any other type of VC-FC module, and any other VC-FC bay group cannot contain a 
FlexFabric module. These module types are incompatible in the same bay group. For more information, see 
the HP Virtual Connect for c-Class BladeSystem Setup and Installation Guide on the Installing tab of the HP 
BladeSystem Technical Resources website (http://www.hp.com/go/bladesystem/documentation). 
When an available port is used for Ethernet, it is no longer available for FC configuration, and vice-versa. 
Likewise, a port that is removed from a network, shared uplink set, or fabric becomes available for 
configuration of another network or fabric. 
The FlexFabric VC module requirements also imply some additional constraints with current VC FC 
requirements for bay groups. When a network is configured on a FlexFabric module using FC-capable ports, 
those ports across the bay group are configured as Ethernet ports, becoming unavailable for FC. The similar 
case applies when selecting the port type as FC. 
There is a limitation on the NC551i LOM and the NC551m mezzanine card. FCoE and iSCSI connections 
are not supported on the same adapter at the same time. By default, if a FlexFabric module is found in the 
enclosure, FCoE connections are created for each server profile. If you do not wish to configure FCoE 
connections, delete the default connections to allow the ports to be used for other connections, such as iSCSI 
or additional Ethernet connections. To delete the connections, right-click the connection, and then select 
Delete Connection. 
There are additional limitations with the supported LOMs and mezzanine cards that support FlexFabric 
configurations. Both FCoE boot and PXE can be configured on the same port with the NC551i LOM and the 
NC551m mezzanine card on different physical functions. Alternatively, iSCSI and PXE can be configured on 
the same port. Only one physical function can be configured for FCoE on a port.  
When configuring FCoE connections, the port speed can be set to 1Gb, 2Gb, 4Gb, 8Gb, custom, preferred, 
or disabled. The port speed is limited to a total of 10Gb, which must be shared between all defined 
connections for that port. The custom speed allows you to better control the bandwidth between FC and 
Ethernet connections. Valid custom speeds are between 100Mb and 10Gb, in 100Mb increments. After all 
connections are defined for a port, the actual allocated bandwidth is calculated by VCM. For bandwidth 
information, see “Bandwidth Assignment (on page 169)." 
PXE settings 
Virtual Connect Manager supports three PXE options: 
•  Enable—VC Manager sends a configuration update to the mezzanine NIC or embedded NIC 
associated with the port to enable PXE operations. 
•  Disable—VC Manager sends a configuration update to the associated mezzanine NIC or embedded 
NIC to disable PXE operations. 










