User guide
Virtual Connect server profiles  203 
Column name  Description 
the connection. 
For the HP Virtual Connect 4Gb FC Module, supported speed values include 
"Auto","1Gb","2Gb", "4Gb", and "Disabled". If the value is set to 8Gb, the 
speed is auto-negotiated by Virtual Connect.* 
WWPN 
As of VC 3.70, the actual hardware WWN for mapped connections 
appears. For unmapped connections, FACTORY-DEFAULT continues to 
appear. If the profile is assigned, the WWN assigned to the port appears. If 
the profile is unassigned and the domain is set to show factory default 
WWNs, FACTORY-DEFAULT appears. If the profile is using VC-defined 
WWNs, the VC-defined WWN appears. If the profile is using hardware 
WWNs, FACTORY-DEFAULT appears. 
Mapping 
Server hardware mapping assignment 
Action 
Delete a connection. Connections can be removed starting with the last 
connection in the list. 
FCoE HBA Connections 
Port 
Relative order of the FCoE port on the server receiving the profile 
Connected to 
Bay number of the VC module to which the port is connected 
FC SAN/FCoE Network Name 
Name of the SAN fabric or FCoE network to which the port is connected, or 
Unassigned 
Type 
Type of connection, SAN or FCoE depending on the fabric or FCoE selection 
Status 
Status of the VC module 
Port Speed Type 
Requested speed for the FlexFabric connection.  
If an FCoE network is assigned to the connection, the supported port speed 
types are "Auto", "Preferred", "Custom" and "Disabled". 
If a SAN Fabric is assigned to the connection, the supported port speed types 
are "1", "2", "4", "8", "Preferred", "Custom" and "Disabled".  
For all port speed types, if configured, the maximum allocated port speed is 
determined by the maximum connection speed for that SAN Fabric or FCoE 
network. 
Auto—VCM determines the appropriate port speed based on the available 
bandwidth for the port.  
Preferred—Use the preferred speed of the SAN Fabric or FCoE network 
selected for this connection. If no preferred speed is configured, VCM 
determines the speed. 
Custom—Allows you to select a custom port speed setting between 100Mb 
and the configured maximum connection speed in 100Mb increments.  
Disabled—The FCoE connection is disabled and no bandwidth is allocated. 
1,2,4, and 8Gb—Predefined custom port speed selection that can be used for 
the FCoE connection assigned to a SAN Fabric.  
Allocated Port Speed (Min-Max) 
Allocated bandwidth of the port. See "Bandwidth assignment (on page 
169)." 
WWPN 
As of VC 3.70, the actual hardware WWN for mapped connections 
appears. For unmapped connections, FACTORY-DEFAULT continues to 
appear. If the profile is assigned, the WWN assigned to the port appears. If 
the profile is unassigned and the domain is set to show factory default 
WWNs, FACTORY-DEFAULT appears. If the profile is using VC-defined 
WWNs, the VC-defined WWN appears. If the profile is using hardware 
WWNs, FACTORY-DEFAULT appears. 
MAC 
As of VC 3.70, the actual hardware MAC for mapped connections appears. 
For unmapped connections, FACTORY-DEFAULT continues to appear. If the 
profile is assigned, the MAC address assigned to the port appears. If the 