User guide
Virtual Connect server profiles  217 
•  When a profile is added, the FC/FCoE connections initially displayed are based on the FC/FCoE 
module configuration in the domain. A pair of horizontally adjacent FC/FCoE-capable modules has 
two connections. 
•  Connections can only be added or removed from the bottom. You can only add or delete connections 
at the end of the list. 
•  You can remove connections at any time (one at a time, from the bottom). 
•  If the existing profile connections do not match the current FC/FCoE module configurations, the add 
operation is not allowed. 
•  The current maximum number of per server profile FC/FCoE connections mapped to the same I/O bay 
is four, unless you are using the HP Integrity BL890c i4 Server Blade. 
o  When FlexFabric modules exist in I/O bays 1 and 2, there can be an additional eight FCoE 
connections that will get mapped to LOMs 3 and 4 on the blades in an Integrity BL890c i4 server. 
The BL890c i4 server has CNA LOMs, which enable two FCoE connections to I/O bay 1 (from 
LOMs 1 and 3) and two FCoE connections to I/O bay 2 (from LOMs 2 and 4). 
The following table lists several scenarios that describe how adding FC/FCoE connections affects an existing 
profile. The scenarios are true for FC module configurations and FC modules, as well as FCoE module 
configurations and FCoE-capable modules. 
Scenario  Description  Existing profile 
connections 
Current FC module 
configurations 
Adding profile connections 
1 
Start with modules in Bays 3 
and 4, create a profile, then 
edit the profile and add 
connections. 
Port  Connected to 
1  Bay 3 
2  Bay 4 
—  — 
Bay 3  Bay 4 
—  — 
—  — 
Port  Connected to 
1  Bay 3 
2  Bay 4 
3  Bay 3 
4  Bay 4 
Add connection, 2 times 
2 
Start with modules in Bays 
3–6, create a profile, then 
edit the profile and add 
connections. 
Port  Connected to 
1  Bay 3 
2  Bay 4 
3  Bay 5 
4  Bay 6 
—  — 
Bay 3  Bay 4 
Bay 5  Bay 6 
—  — 
Port  Connected to 
1  Bay 3 
2  Bay 4 
3  Bay 5 
4  Bay 6 
5  Bay 3 
6  Bay 4 
7  Bay 5 
8  Bay 6 
Add connection, 4 times 
3 
Start with modules in Bays 3 
and 4, create a profile, 
install modules into Bays 5 
and 6, then edit the profile 
and add connections. 
Port  Connected to 
1  Bay 3 
2  Bay 4 
—  — 
Bay 3  Bay 4 
Bay 5  Bay 6 
—  — 
Port  Connected to 
1  Bay 3 
2  Bay 4 
3  Bay 5 
4  Bay 6 
Add connection, 2 times 