Virtual Connect modules  230 
•  FC modules in multi-enclosure double dense domains 
When using VC-FC modules, multi-enclosure double dense domains require similar and compatible 
VC-FC modules in bays 5, 6, 7, and 8 in all enclosures. If a multi-enclosure double dense configuration 
contains incompatible VC-FC modules in bays 5, 6, 7, or 8 in either the local or remote enclosures, 
some or all of the compatible VC-FC modules in the remote enclosures might be designated 
INCOMPATIBLE after import. 
Corrective action: 
a.  Replace incompatible VC-FC modules with similar and compatible VC-FC modules in bays 5, 6, 7, 
and 8 in all enclosures. 
b.  Power cycle any VC-FC module that still remains in an INCOMPATIBLE state. 
Ethernet Bay Summary (General Information) screen 
This screen provides a summary of the interconnect module status and general information. To remove a 
module, see "Interconnect module removal and replacement (on page 262)." 
The following table describes the rows within the Interconnect Bay Status table. 
Row  Description 
Overall Status 
Represents the worst condition of OA Reported Status, VC Status, and OA 
Communication Status 
Hardware Status 
Component health status from the Onboard Administrator 
VC Status 
Component health status from the Virtual Connect Manager 
OA Communication Status 
Current Virtual Connect Manager to Onboard Administrator communication 
state 
Rack Name 
Name of the enclosure rack (assigned through the Onboard Administrator) 
Enclosure Name 
Name of the enclosure (assigned through the Onboard Administrator) 
Bay 
Number of the bay being summarized on this screen 