General remarks
The SES-imagotag VUSION Labels must be installed according to the mounting instructions
of the producer. In rare cases it may occur that the usage of wireless appliances is restricted
by the building owner (e.g. Airport or Hospital). Please contact the appropriate authorities
before installing the SES-imagotag VUSION Labels.
Environmental
General
E-Paper displays are moisture and UV sensitive. The absolute rating operating environments
describes the boundary conditions for updating the display while the absolute rating storage
environment (see Storage and warehousing) describes the boundary conditions for a display
not updating.
BW
BW (Wide temp/Freezer)
BWR
Operating temperature
0° C to +45° C
-25° C to +30° C
10° C to +40° C
Operating temperature
for maximum lifetime
21° C
21° C
21° C
Operating humidity
30% - 80%
30% - 80%
35% - 70%
Cleaning Instructions
Clean the electronic label with the help of a damp cloth. Use only common household
cleaners.
Do not clean the label with alcohol, solvents and / or abrasive cleaning products.
Note: Do not use liquid or aerosol cleaners and keep it away from water.
Temperature and Humidity Conditions
High humidity combined with low temperature are not recommended.
Low temperature will reduce the battery lifetime.
Storage and warehousing
While displays are rated to perform according to specification for the warranty
period at the absolute specified operating environment, the better the storage condition, the
better the E-Paper displays will perform. Like other moisture and UV sensitive components,
we recommend that our labels are stored in temperature and humidity-controlled
environments, and whenever possible, under below defined Optimal Storage Conditions,
away from sunlight, to optimize their performance.
It is strongly recommended to observe the following points to ensure the best operation,
functioning and battery lifetime:
Storage temperature and humidity
BW
BW (Wide temp/Freezer)
BWR
Storage temperature
-20° C to +50° C
-20° C to +50° C
-20° C to +50° C
Storage humidity
30% - 80%
30% - 80%
40% - 70%
Optimal storage temperature
0° C to +30° C
0° C to +30° C
0° C to +30° C
Optimal storage humidity
(non-condensing)
40% - 60%
40% - 60%