Installation Guide MODEL 524 Pressure Transducers 1-800-257-3872 TOLL FREE 1-978-264-0292 FAX www.Setra.
Setra offers a complete line of products for these industries: Industrial HVAC Test & Measurement Barometric Ultra High Purity / Sanitary
Please Note: The 524 series is designed and manufactured in accordance with sound engineering practice as defined by the Pressure Equipment Directive 97/23/EC. This product must not be used as a “safety accessory” as defined by the Pressure Equipment Directive, Article 1, Paragraph 2.1.3. The CE Mark on the unit does not relate to the Pressure Equipment Directive.
* The pressure transducer has no means of draining or venting, this must be performed by another component in the end users system. * Pressure range must be compatible with the maximum pressure being measured. * Pressure media must be compatible with the transducer wetted parts listed in these instructions. * Liquid must not be allowed to freeze in the pressure port. MECHANICAL INSTALLATION The pressure transducers have been designed for measuring hydrostatic level by suspension from the cable.
OPERATIONAL LIFE: Limited to 100M cycles to maximum allowable pressure. WARRANTY We guarantee this instrument against faulty workmanship and material for a period of two years from date of delivery. The Company undertake to repair, free of charge, ex-works any instrument found to be defective within the specified period providing the instrument has been used within the specification in accordance with these instructions and has not been misused in any way.
MAINTENANCE Routine Inspection: Not required except for periodic inspection of the cable and connector to ensure that these are neither damaged nor softened by incompatible liquid. TABLE 1 ELECTRICAL CONNECTIONS mV Type Number Connector 524-BP Cable 524-11 Cable 524-2C Cable 4-20mA In+ Out+ Out- In- Earth R Y B W Drain Output Supply Voltage BP 0 to 100mV 10V d.c. 11 4 to 20mA 8 – 28V d.c. 2C 0 to 10V 13 to 28V d.c.