Operating instructions

3
Contents (cont’d)
7.5 SETUP ALARM SCREEN .............................................................. 21
  7.5.1 Alarm Setup Operation ......................................................................................................21
  7.5.2 Entering Data .........................................................................................................................21
    7.5.2.1 Mute Time Out/Alarm Delay ..................................................................................
21
  7.5.3 Data Entry Screen .................................................................................................................
21
7.6 SELF TEST SCREEN ............................................................................................ 22
  7.6.1 Self Test Operation ..............................................................................................................22
7.7 CALIBRATION SCREEN ............................................................................22
  7.7.1 Calibration ..............................................................................................................................22
8.8 Pressure Monitoring Screens ................................................................23
9.0 Maintenance ...........................................................................................25
9.1 Cleaning ..................................................................................................25
10.0 Agency Electrical Standards ................................................................25
11.0 SRPM Specifications ...........................................................................26
12.0 Electrical ................................................................................................27
13.0 RETURNING PRODUCTS FOR REPAIR .................................................. 28
14.0 Warranty and Limitations of Liability .................................................28
26
11.0 SRPM Specifications 
Performance Data
Accuracy RSS* (at constant temp.)  ±0.5%
Non-Linearity (Terminal Method)  ±0.35%
(BSSL Based)  ±0.25%
Hysteresis  ±0.05%
Non-Repeatability  ±0.05%
Zero Setting Tolerance  ±0.5% FS
Span Setting Tolerance  ±0.5% FS
Thermal Effects**
Compensated Range °F (°C)  ±0.03% FS (±0.05% FS)
Overpressure  ±1 psi
* RSS of Non-Linearity, Non-Repeatability and Hysteresis
**Units calibrated at nominal 70°F. Maximum thermal error computed from this datum.
Environment Data
Temperature 
 Operating* °F (°C)   +32 to 120 (0 to +50
 Storage °F (°C)  -20 to +160 (-30 to ±70)
Operating Humidity  5 to 95% RH (Non-condensing)
 *Operating temperature limits of the electronics only.
Physical Description
Case  Fire Retardant Plastic (NEMA 1 Rated for Indoor Applications)
Dimensions  8”H x 5.4”W x 1/8”D
  (20.3H x 13.7W x 4.1D cm)
Electrical Connection  Removable Terminal Block
Pressure fittings  Barbed Fittings for 1/4” Tubing
Weight (approx.)  1.5 lbs (680g)
Mounting  (Mounts to double gang electrical box.)
Display 
LCD  128 x 128, RGB Backlit
Status Indicators  Green LED, Normal; Red LED, Alarm; Backlit LCD
Electrical Data (Voltage) 
Circuit  3-Wire (Exc., Out, Com)
Output*  0 to 5 VDC
  0 to 10 VDC
Excitation 
 Code V1  85-265 VAC, 50-60 Hz
 Code A1  18- 32 VAC, 50-60 HZ
Power Consumption  5W
Alarm Output  SPDT Relay
  1A @24 VDC
  1A @ 120 VAC
*Calibrated into a 50K ohm load, operable into a 5000 ohm load or greater.
Electrical Data (Current) 
Circuit  2-Wire
Output  4 to 20 mA
External Load  0 to 510 ohms
Excitation 
 Code V1  85-265 VAC, 50-60 Hz
 Code A1  18- 32 VAC, 50-60 HZ
Pressure Media  Air or Nonconductive, Nonexplosive Gases.