Datasheet

ST-352UAG-05E
INPUT CHARACTERISTICS:
VOLTAGE: 90VAC ~ 264 VAC
FREQUENCY: 50 ~60
HZ
INPUT CURRENT: 10.0A (RMS) FOR 115VAC
6.0A (RMS) FOR 230VAC
INRUSH CURRENT: 50 A MAX
SPECIFICATION:
EFFICIENCY: 68% TYPICAL, FULL LOAD CONDITION AT 115/230 VAC
POWER GOOD SIGNAL: ON DELAY TIME 100 ~ 500 ms, OFF DELAY TIME 1ms.
HOLD UP TIME: 17ms AT 25 FULL LOAD CONDITION AT 115/230 VAC INPUT.
OPERATING TEMPERATURE RANGE: 0℃ ~ 50℃.
REMOTE ON/OFF CONTROL: THE POWER SUPPLY OUTPUT SHALL BE ENABLED WITH AN
ACTIVE-LOW TTL SIGNAL. WHEN TTL SIGNAL IS LOW, THE DC OUTPUTS ARE TO BE ENABLED.
WHEN TTL SIGNAL IS HIGH OR OPEN CIRCUITED, THE DC OUTPUTS ARE TO BE DISABLED.
OVER POWER PROTECTION: AT 115/230 VAC INPUT THE POWER SUPPLY WILL SHUT DOWN
ALL DC OUTPUT WITH IN 105% TO 140% OF FULL LOAD.
OVER VOLTAGE PROTECTION: +5V 6.5V, +12V 14.5V, +3.3V 4.5V.
EMI REQUIREMENT: FCC PART 15 SUB PART J CLASS B AT SYSTEM LOAD, CISPR 22 CLASS B.
SAFETY: c UL, TUV, CB, CCC, FCC, BSMI, CE
DIMENSION: 200 (D) x 100 (W) x 70 (H) mm.
COOLING: ONE 60mm DC FAN.
ACTIVE POWER FACTOR CORRECTION: EN 61000-3-2: 1995+A1+A2: 1998, CLASS D.
OUTPUT CHARACTERISTICS:
OUTPUT CURRENT REGULATION OUTPUT
OUTPUT
VOLTAGE
MIN [A] MAX [A] LOAD LINE
RIPPLE
MAX [P-P]
NOISE
MAX [P-P]
+5V 1.0 25 ±5% ±1% 50mV 50mV
+12V1 1.0 25 ±5% ±1% 120mV 120mV
+3.3V 1.0 17 ±5% ±1% 50mV 50mV
-12V 0 0.8 ±10% ±1% 120mV 120mV
+5VSB 0 2.0 ±5% ±1% 50mV 50mV
1. MAXIMUM CONTINUOUS COMBINED LOAD ON +5V AND +3.3V OUTPUTS SHALL NOT EXCEED 125W.
2. MAXIMUM CONTINUOUS COMBINED LOAD ON +5V, +3.3V, +12V OUTPUTS SHALL NOT EXCEED 334W.
3. MAXIMUM CONTINUOUS TOTAL DC OUTPUT POWER SHALL NOT EXCEED 350W.
Ver. 1.0

Summary of content (1 pages)