FW2170 User’s Manual FW2170 User’s Manual (Product Guide) Version 4.16(Rev.E) Sep. 27, 2012 Class A Digital Device (industrial & commercial environment) This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to CE and FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
FW2170 User’s Manual FW2170 User’s Manual Document Part Number: M4067-00 Document Version: 4.16(Rev.E) Revised: September 27, 2012 About This Document This document is prepared for users of FW2170 supplied by Seyeon Tech Co., Ltd. It is assumed that the users are familiar with Microsoft Windows operating systems and Web browsers such as Internet Explorer.
FW2170 User’s Manual Contents 1. PRODUCT OVERVIEW ......................................................................................................................... 5 1.1. FW2170 ........................................................................................................................................................................ 5 1.2. KEY FEATURES ...................................................................................................................................
FW2170 User’s Manual 5. 6. SYSTEM CONFIGURATION MENU .................................................................................................. 18 5.1. SERVER NAME SETUP...................................................................................................................................................19 5.2. ADMIN PASSWORD ......................................................................................................................................................
FW2170 User’s Manual 1. Product Overview 1.1. FW2170 FlexWATCH™ 2170 is a stand-alone 4ch network media decoder which converts four streams of Motion JPEG or H. 264 from 4 different FlexWATCH™ Video/Camera servers in real-time into the high quality analog signals. It support 4 screens output and the FlexWATCH™ Video/Camera input sources from the encoder device The server of FlexWATCH™ 2170 Network media decoder is used in combination with FlexWATCH™ video & camera servers.
FW2170 User’s Manual 1.2. Key Features Decodes network video without the need of a PC Provides four channels of video up to 30fps decoding 1.3M per each channel. Single Serial interface for Voice kit. Two way voice communication will be supported by software upgrade later. Single RS-485, RS-232 interface for future use. It can be used for Pan Tilt Zoom device control using controller. Supports dynamic IP at remote site using IPCCTVDNS. Built-in Web server for administration.
FW2170 User’s Manual 1.3. Preliminary Specification FW2170-DB Model CPU OS Flash SDRAM System Output Video Input HDMI : HDMI Connector Component : RCA Connector Composite : BNC Connector M-JPEG, H.264 IP stream ( JES format stream only ) Max Decoding resolution Performance Max Rate Interoperable Devices Audio Codec Network 32bit Embedded Processor Embedded Linux 128M Byte 128M Byte Protocol Network I/F LAN Serial I/F RS-232 RS-485 Alarm I/F DI/DO Management 1.
FW2170 User’s Manual 1.4. FW2170 Packing List FW-2170 1ea Power Supply Unit 1ea (Power Cable & SMPS DC12V 1A Adapter) CD (User’s Manual, installation wizard and Pictures) 1 ea Table 2 : FW2170 Packing List Note: Please check all the listed items are included in your package. For any missing items, please contact your local distributor. M4067-00 8 Seyeon Tech Co.
FW2170 User’s Manual 1.5. Network Diagram FW2170 works over IP network such as leased line, cable model, XDSL modem, PSTN modem. FW2170 can also works over public network or private network. The network environment will vary with users’ goals and needs; however, basic applications with FW2170 can be as below. 1.5.1. Private Network Private network without Internet connection. 1.5.2.
FW2170 User’s Manual 1.5.3. FW-2170 with the existing Analog System FW2170 decode and transmits Video stream to analog system so that it an can be applied with Video Matrix. M4067-00 10 Seyeon Tech Co.
FW2170 User’s Manual 1.6. Application FW2170 is born to provide reliable and flexible TCP IP network in the remote video surveillance industry. Decoded Video stream by FW2170 can be monitored on standard TV or Audio/Video Devices. Users easily monitor, search, and save Video stream by FlexWATCH By combining with FlexWATCH M4067-00 TM TM server and FW2170 efficiently. server series, following can be suggested application area.
FW2170 User’s Manual 2. Hardware Description 2.1. Front View D E A B C Picture 2 : FW2170 Front View Name A LAN LINK LED B Power LED C Factory Default Button D CONTROL E Display Mode Switch Description Green light blinks when LAN is physically connected Red light blinks when power is provided This button can reset the factory default settings at the system. Keep pressing FD button for about 5 seconds, after reboot the system. While pressing this button, ACT LED is flickering.
FW2170 User’s Manual 2.2. Rear View C B D E F G Picture 3 : FW2170 Rear View A Name Description A Component B V-OUT C MIC Audio Input Port D SPK Audio Output Port E HDMI HDMI Port F LAN LAN Connector (10/100BaseT Ethernet auto sensing) G POWER ON/OFF Component Port Composite Port (Video Output Port) Power (DC 12V/1A [SMPS]) Table 4 : FW2170 Rear View M4067-00 13 Seyeon Tech Co.
FW2170 User’s Manual 2.2.1. CTL Port Description It’s RS-232 port for Serial input device, Modem or Console (Hyperterminal.connection). For RS-232 connection, RXD, TXD and GND are used. For connection to PC, RXD and TXD are used. RXD and TXD should be cross to communicate properly Picture 4 : CTL Port Description 2.2.2. Speaker V-out Jack Description Jack information for Mono Speaker or Video Out Jack. 1 : GND 2 : SPK 3 : V-OUT Picture 5 : V-out Jack 2.2.3.
FW2170 User’s Manual 3. FW2170 Installation and Basic Setup 3.1. Before Installation Read carefully User's Manual. Check User’s Network (IP Address, Network Mask and default gateway) Secure IP address for FW2170. 3.2. Factory Default Settings The following table shows the factory default condition. Please refer to this when you need to change the values on admin menu. Factory Default Admin ID root Admin password root IP address 10.20.30.40 Network mask 255.255.255.0 Gateway 10.20.30.
FW2170 User’s Manual Input ID and Password of Admin. (Default ID : root / Default Password: root) 2) If you succeed in connecting to FW2170 Network Decoder System, “Display Output Device” menu will be shown on the right side immediately and whole menus on the left side. Because, you mainly need this menu “Display Output Device” while using FW2170. M4067-00 16 Seyeon Tech Co.
FW2170 User’s Manual 4. Admin Menu After connecting to a FlexWATCH™ server on the web browser, you’ll find the web page as shown below. The rightmost item of the menu is Admin, where you can set up the most of features in the FlexWATCH™ Server you’re connecting to. 4.1. Entering Admin Menu Click “Admin” item of the menu, then you’ll see a login window. In the login window, enter “root” for both ID and password as they are the factory defaults. Press Enter key or click “OK” button.
FW2170 User’s Manual 4.2. Admin Menu Structure The following table shows the hierarchy of the Admin menu structure that we’re going to deal with in this manual. Category Main Menu System configuration Server Name Admin.
FW2170 User’s Manual 5.1. Server Name Setup Click Step 1 on Quick Configuration, then the following will be displayed and you will find out the system information such as model name of the FlexWATCH™ Server, server name, MAC address (serial number), firmware version, and Web image version. As an administrator, you can change the name of the server name, but other values are not allowed to change. To change the server name, enter a new server name in the Server Name filed.
FW2170 User’s Manual 6. Network Configuration Configuration the network is dependent on how an IP address is assigned in Ethernet-based environment, which is static IP, dynamic IP (DHCP). For wireless LAN, additional configuration is necessary to have a connection with wireless AP. In the case of wireless models, users have to choose between wired or wireless connection. In other words, both connections can’t be used at the same time.
FW2170 User’s Manual click apply for saving settings. After “Apply”, program will ask closing web browser for updates, which will take 20~30 seconds. If “Back” button is pushed while configuration, all values will be discarded. If “Refresh” button is pushed, the program will load previous values. Note: If the HTTP port number is changed to other value than default (80), make sure the new HTTP port number goes together with the FlexWATCH™ Server's Internet address.
FW2170 User’s Manual 6.3. View Network Status This menu shows network status of FW products. Wireless LAN status will be added for wireless models. 6.4. Network Status Notify This feature helps to send updated network status information to registered email address if any changes happen. This function will work under DHCP or PPPoE.
FW2170 User’s Manual First, select Enable to use the feature. Then enter the address of the SMTP server which is needed for email service. If your SMTP server requires a user ID and a password for authentication, you will have to get them from ISP or network admin. Enter the ID and password. In Sender field, enter your email address or other meaningful words that will show the message was sent from the FlexWATCH™ server as a notification.
FW2170 User’s Manual 7. Display Configuration You can configurate Display mode of FW2170 connected to FlewWATCH™ cameras in this part of Display Configuration, for properly controlling analog monitor according to each of channel. Before viewing the monitor, you have to configure Display Output Device first and then register the information about each channel of FlewWATCH™ cameras. But FlewWATCH™ server is required in advance for video stream running. 7.1.
FW2170 User’s Manual Option Details for Display Output Device Configuration are as below. Display Output: Composite, Component, HDMI Video Output Format: NTSC, PAL OSD Service: Turn on, Turn off OSD Menu: Motion Status, Connection, Channel Name, Time, PTZ Status Audio: Disable, Listen Only, 2Way Initial Channel: Ch1, Ch2, Ch3, Ch4, Rotation Single Channel Rotation Channel Dwelling Time (sec): The Default value is7 ( 7~300) 7.1.1.
FW2170 User’s Manual 8. Device Configuration You set up the connection between FlexWATCH™ Server and the camera in this part of configuration. That includes Video data, external devices, Input / Output, Alarm control, and etc. 8.1. Device Number Configuration Click “Device Number Configuration” of Device Configuration. Input Device number of FW2170 Click “Apply” button to save the change. If you do not want to save, click “Back” button. 8.2.
FW2170 User’s Manual 8.2.1. Transparent Mode When there are two FlexWATCH™ Servers present on the network, they can act like a transparent interface between two different UART devices so that the communication between the UART devices can be made transparently without a flaw.
FW2170 User’s Manual 9. Utilities In Utilities part of the Admin menu, you can view the system log file, save the changed value during the configuration, reboot, restore the factory default condition, and update the system. 9.1. Reboot It is recommended to reboot the system after making changes and saving the configuration. To reboot, click “Reboot" on Utilities menu.
FW2170 User’s Manual Click “Factory Default” on Utilities menu. A confirmation screen will be displayed as shown Click “Factory Default” button, otherwise click “Back” button to cancel it. The second confirmation screen will appear. Click “OK” button to restore the factory default condition right away. If you click “Cancel”, web browser will go back to the previous screen without any change made. 9.3.
FW2170 User’s Manual Web Only Update: Only Web image is to be updated. Up-to-date system files can be downloaded in Support page of Seyeon Tech’s homepages at http://www.flexwatch.com. After the update is done, it is required to reboot the server. 9.3.1. All (Kernel, RAM disk, System, Web) Update Click the “Start” button next to All (Firmware, RAM disk, System, Web) Update item on the menu, and a confirmation window will appear. Click “OK” button to proceed the update, otherwise click “Cancel”.
FW2170 User’s Manual Now you can check the file name and the size in the new window. If you want to go back to the previous stage, click the “Previous” button. Click the “Next” button to update the firmware right away and proceed to next stage. If you want to stop the update process, click the “Cancel” button. The next window is for locating the RAM Disk Update file. Go through the same steps as in Firmware Update, and do the same in update process for System and Web Update files.
FW2170 User’s Manual Now the final confirmation window will appear. Click “Reboot” button and the system will reboot. 9.3.2. System and Web Update Click the “Start” button next to System and Web Update item on the menu, and a confirmation window will appear. Click “OK” button to proceed the update, otherwise click “Cancel”. Go through the same steps as in All Update process (Kernel and RAM Disk updates are not made here). After update is done, click “Reboot” to start the system over. 9.3.3.