Technical data

Loading the Single Connector Assembly (SCA) Drives Into the System
63
Loading the Single Connector Assembly (SCA) Drives Into the System
The SGI 2400 and 2800 use an SCA sled assembly for mounting into the drive bay. Disk
drive modules are aligned vertically at the front of the chassis, as shown in Figure 5-2.
Note that the leftmost disk drive—the system drive—is oriented differently from the
others.
The drive bays in the modules use single-ended, ultra SCSI drives only. The server’s SCSI
drive box enclosure can support other types of drives, depending on how the box is
configured.
To insert a disk module, follow these steps:
1. If necessary, snap the handle to the open position so that it is centered, as shown in
Figure 5-2.
2. If you are adding a drive, remove the drive filler plate that covers the drive slot you
want to use.
3. Align the new disk module with the drive guide, as shown in Figure 5-2.
4. Gently but firmly slide the disk module on the guides over the pin.
5. When the disk module is all the way in, snap the handle right to the closed position,
as shown in Figure 5-2. In the case of the system disk module, which is upside
down relative to the other drives, snap the handle left.