User guide
I/O Devices
007-5900-001 9
Table 1-4 identifies the various I/O connections shown in Figure 1-6 and Figure 1-7.
Hard Disk Drives
The UV 20 server supports a maximum of 8 x 2.5” hard drives. For instructions on installing hard
drives, “Installing Hot-Swap Hard Drives” on page 32.
Notes:
• SAS drives are only supported when proper Intel RAID C600 Upgrade Key or Intel
Integrated RAID Module is installed.
• Drives can consume up to 17 watts of power each. Drives must be specified to run at a
maximum ambient temperature of 45ºC.
Slimline Optical Drives
The slimline optical drive carrier can be used with a single slimline optical drive. One slimline
carrier is included with your server system. The optical drive must be purchased separately.
The drive in the optical drive carrier is NOT hot-swappable. The system power must be turned off
to insert or remove the slimline optical drive carrier.
Table 1-4 I/O Connections
Label Description
A Slimline optical drive bay
B Hard disk drive bays
C USB ports
D USB ports
E Video port