User's Manual

Table Of Contents
BTP-7400 User’s Manual
- 37 -
3.6 Physical distance setting
Caution
This function can be put into use only after getting the manufacturers
authorized password.
This function is used to set the physical distance between various
components of the printer in the unit of dot. For 203DPI, 1 mm
equals to 8 dots; for 300DPI,1 mm equals to12dots.Set method:
Menu Settings Physical distance Settings →Enter password
→Set related parameters. Content can be set are as following:
Setting
Application method
Remarks
From print head
to transmission
sensor
Distance from print head to
transmission sensor, using to
adjust the print position
To be effective when
transmission sensor is
selected
From print head
to reflective
sensor
Distance from print head to
reflective sensor, using to
adjust the print position
To be effective when
reflective sensor is
selected
From print head
to tear-off bar
Distance from print head to
tear-off bar, using to adjust the
tear-off position
//
From print head
to peel-off
sensor
Distance from print head to
peel-off sensor, using to adjust
the peel-off position
//
From print head
to cutter
Distance from print head to
cutter, using to adjust the cut
position.
//