User's Manual
Table Of Contents
- 1 Product introduction
- 2 Printer installation
- 3 Printer operation
- 3.1 Print head pressure and pressure position adju
- 3.2 Sensor position adjustment
- 3.3 Function of indicator light, button and LCD
- 3.4 Function of calibration
- 3.5 Print settings
- 3.6 Physical distance setting
- 3.7 Serial interface settings
- 3.8 Network Settings
- 3.9 Parallel interface settings
- 3.10 Date and time
- 3.11 Offline printing
- 3.12 Service
- 3.13 Consumables library
- 3.14 File operation
- 3.15 Printer debugging
- 3.16 Sensor settings
- 4 Routine maintenance
- 5 Troubleshooting
- Appendix
- Appendix 1 Technical specification
- Appendix 2 Self-test page
- Appendix 3 Print and paper output position
- Appendix 4 Communication interface
- Appendix 5 Guide for paper loading under peel-off
- Appendix 6 Guide for paper loading under label rew
- Appendix 7 Guide for paper loading under cutter mo
- Appendix 8 Menu on human-machine interface
- Appendix 9 FCC statement
BTP-7400 User’s Manual
- 53 -
mode via this operation. Also, the printer can exit from the DUMP
mode via the FEED button.
3.16 Sensor settings
Caution
This function settings need password authorized by the manufacturer.
1) Light emission intensity
Query and set the light emission intensity of sensors, including the
transmissive sensor, reflective sensor and ribbon sensor. The
parameters of light emission intensity are generally obtained by the
calibration function (see 3.4 Function of calibration).
2) Reference threshold value
Query and set the threshold value of each sensor, used to judge
the reference value of paper end or marks for continuous paper or
non-continuous paper. The parameters of threshold value are
generally obtained by the calibration function (see 3.4 Function of
calibration).
3) Sensor selection
Select the sensor to be used (reflective or transmissive sensor)
according to the current paper type used (correspondence
relationship refer to Table 3.5.1).
4) Sensor calibration
The user can use this function to adjust the light emission intensity
of sensor to the target AD, and calibrate the transmissive sensor,