Specifications
L506 Hardware Design 
Copyright©  Shanghai  Mobiletek  Communication  Ltd                                                              40 
3.9 Power on/off and reset interface 
3.9.1 Pin definition 
L506 can be powered on by pulling PWRKEY pin down to ground. This pin is already internal pulled 
up to 1.8V in module, so external pull-up resistor is not necessary. Placing an ESD protection diode 
close  to  the  PWRKEY  pin  is  strongly  recommended.  Please  refer  to  the  following  figure  for 
recommended reference circuitL506 also have a RESET pin to reset module. This function is used as 
an emergency reset only when AT command “AT+CPOF” has no effect. User can pull RESET pin to 
ground, then module will reset. Placing an ESD protection diode close to the RESET pin is strongly 
recommended.  Please  refer  to  the  following  figure  for  recommended  reference  circuit,  you  can 
pull-down this pin to ground and hold about 150us and then release will force the module enter reset 
state. 
Table 3-15power on/off and reset key define 
Pin No. 
Net name 
I/O Typ. 
descriptions 
3 
PWRKEY 
DI  
L506 power on/off pin(internal pull-up to 
1.8V) 
4 
RESET 
DI 
L506 RESET pin(internal pull-up to 1.8V) 
Note: Due to the internal partial pressure, the actual measured value of the user is about 0.8v. 
3.9.2 Power on sequence 
Table 3-16 power on timing chart. 
Ton 
Power on low level pulse 
115 
150 
-- 
ms 
Ton(status) 
Power on time(According to the 
STATUS pin judgment) 
2.76 
-- 
25 
s 
Ton(uart) 
Power on time (according the UART 
pin judgement) 
2.5 
-- 
20 
s 
VIH 
Input  high  level  voltage  of 
PWRKEY pin 
1.17 
1.8 
2.1 
V 
VIL 
Input low level voltage of PWRKEY 
pin 
-0.3 
0 
0.3 
V 