Specifications
L506 Hardware Design 
Copyright©  Shanghai  Mobiletek  Communication  Ltd                                                              41 
Figures 3-17Power on Timing sequence 
Note: the STATUS pin can be used to identify whether has been power on, when the module has 
access to electricity and initialization is completed, the STATUS output high level, or has 
maintained low level. 
3.9.3 Power off sequence 
The following methods can be used to power down. These procedures will make module disconnect 
from the network and allow the software to enter a safe state, and then save data before completely 
powering the module off. 
● Method 1: Power off L506 by pulling the PWRKEY pin down (This function needs to apply 
to our company) 
● Method 2: Power off L506 by AT command  “AT+CPOF” 
● Method 3: over-voltage or under-voltage automatic power down.   
● Method 4: over-temperature or under-temperature automatic power down. 
Note: 1. About the AT command “AT+CPOF” detail please refer document [1]. 
 2. Over-voltage or under-voltage may cause automatic power down. 
3. Over-temperature or under-temperature may cause automatic power down. 
3.9.4 Reset sequence 
L506 can lower module RESET pin to restart the module. 
Table 3-17 Reset pin electrical properties 
Symbol 
Net name 
Min. 
Typ. 
Max. 
Unit 
Treset 
Reset pin low level hold time 
180 
600 
-- 
us 
VIH 
Reset pin input high level 
1.17 
1.8 
2.1 
V 
VIL 
Reset pin input low level 
-0.3 
0 
0.3 
V 