8
2. Electrical Parameters
2.1 Operating Conditions
EMW3081 input voltage falls below the minimum rated voltage will cause instability. Must note
this point when designed power supply.
Table2.Inputvoltagerange
Symbol Description Condition
Detail
Min Typ Max Unit
VDD Power supply 3.0 3.3 3.6 V
Stresses above the absolute maximum ratings may cause permanent damage to the device.
These are stress ratings only and functional operation of the device at these conditions is not implied.
Exposure to maximum rating conditions for extended periods may affect device reliability.
Table3.Ratedvoltageparameters
Symbol Description Min Typ Unit
VDD
The input voltage of Module power supply
–0.3 3.6 V
VIN The pin’s input voltage of GPIO −0.3 3.6 V
2.2 Power Parameters
Table4.EMW3081powerparameters
Condition Current(3V3) Description
Deep sleep
16 uA
Waked up by low power timer and GPIO
triggering
Sleep 19 mA Stay connected but no data transfer
Only CPU operation mode 33 mA
CPU clock at 166MHZ, UART/SPI/I2C is
available, Wi-Fi is unavailable
11n RX mode 61 mA
CPU clock at 166MHZ, UART/SPI/I2C is
available, Wi-Fi operates in 11n RX data
rece
p
tion mode