User's Manual

PropertyofTCPInc
ProprietaryandConfidential
damage
  3)Ramprate2C/min  3)Remainfullfunctionalatsameperformance;
noappearancedamage
  4)80thermalcycles4)Solidsolderjoint

2 ThermalCycling(Operating)0
degCto45degC
1)Ramprateat0.5DegC/Min 5 4 1)Allthepartsnormally
 2)Dwelltime3hrs2)Rapidramptosurfaceanyweakjointsno
damage

  3)12cycles3)Remainfullfunctionalatsameperformance;
noappearancedamage

     4)Solidsolderjoint

3 StorageTest 1)High/LowTemperatureTestatlowHumidity
(60C,20%RH,‐10C)
7 2Remainfullfunctionalatsameperformance;
noappearancedamage

  2)High/LowTemperatureTestathighHumidity(60C,
80%RH,‐10C)
  

4 DropTest
1) Height of drop: 1m (Free drop onto the wooden floor)
3
1) The function of key components should be
normal after the test.

 
2) Number of drop: one time on 6 faces (left, right, front, rear,
bottom and top side).
2) Appearance shouldn't be cracked or other
damage.

 
3) DUT status: with battery inserted
3) Battery cover or battery separate from
handset is allowed (if any)

 

4) It's acceptable that recover the separation
between upper and bottom panels except
crack.



5 Keypad/ButtonLifeTest
1) Test times: 20,000 times with metal dome
 4
1) The function of key components should be
normal after the test.

 
2) Force: 200gf
 
 
3) Frequency: 4.8Hz
 
 
4) Test Sample Status: Power-off
  


6 BatteryLifeTest
a) Measure current/voltage of the tested unit when 1)Batteries
just installed and 2) The 5 LEDs turn ON before the test.
 1
 
b) Using the group button “1-4” on the remote to pair with a
light-bulb.
  
 
c) After pairing, select the group button then press the on/off
button. You should see the light-bulb turn on and off as well.
  
C:\Documents