SECD-7I0A-35 User Manual SECD-7I0A-35 User Manual
SECD-7I0A-35 User Manual General introduction SECD-7I0A-35 is a monitoring and control platform specially designed for construction machinery and agricultural machinery of Shanghai Rising Digital Co.,Ltd. The display is based on ARM platform and adopts TFT industrial LCD with resolution of 7.0 inches and 800 x 480. It has good humancomputer interaction performance.
SECD-7I0A-35 User Manual table of Contents Functions and Characteristics ............................................................................................................ 1 1、Integration of Control, Display and Communication ............................................................................ 1 2、Special display and control development environment........................................................................ 1 3、Adapt to harsh environment.......................................
SECD-7I0A-35 User Manual Functions and Characteristics 1、Integration of Control, Display and Communication Display: Delicate and practical industrial TFT LCD screen, which can display various components. Video: Support NTSC, PAL analog camera, support single, 4-segment, picture-in-picture display mode Communication: support a variety of wired and wireless communication technologies, compatible with J1939/CANOpen/CAN2.0B protocol; support USB programs and fast image download Function NO.
SECD-7I0A-35 User Manual Power supply anti-reverse connection design, greater than 37V self-protection, prevent burnout Suitable for strong vibration, dust, rainwater, lightning and other environment in field operation 4、 Seamless connection with remote monitoring system Support remote debugging and brushing process to facilitate after-sales maintenance Supporting remote unlocking machine to facilitate creditor's rights management Functional description of External interface 1、 External int
SECD-7I0A-35 User Manual 2、 Installation dimensions Fixed installation with 4 *M6 screw (including spring washer and flat washer) 3、 Plug-in Port Definition Port Definition Terminal name Functional description 1 CAN_L CAN Bus Negative 2 CAN_H CAN Bus forward 4 Remarks Communicate with the controller; program download and debugging
SECD-7I0A-35 User Manual 3 CAMRA1- 4 CAMRA2- No. 1 Camera SignalNo. 2 Camera Signal- 5 CAMRA3- No. 3 Camera Signal- 6 CAMRA4- No. 4 Camera Signal- 7 Reset Program Reset 8 GND GND 9 +12V OUT 10 NC 11 NC 12 CAMRA1+ 13 CAMRA2+ No. 1 Camera Signal+ No. 2 Camera Signal+ 14 CAMRA3+ No. 3 Camera Signal+ 15 CAMRA4+ No.
SECD-7I0A-35 User Manual SECD-710A-35 PC is connected with LM USB simulator through USB, and the other end of the simulator is connected with SECD-7I0A-35 display screen through CAN. Install LM Studio on PC. Complete the construction of hardware platform. When choosing and purchasing products, relevant development and debugging accessories should be equipped at the same time, as shown in the table below.: NO.
SECD-7I0A-35 User Manual LM Studio is installed on PC and the development environment is well configured. It can realize engineering creation, page creation, control addition, script generation, burning, debugging and other functions. See the Help Content under the Help menu of LM Studio Software. LM Studio integrates a large number of mature and easy-to-use component libraries, as follows: No. 1.1 1.2 Large class system kernel system function Task control Process Control 2.
SECD-7I0A-35 User Manual Implementing a class of functions for discrete manufacturing and batch process industries related Time function 5.1 to time and output with switching and analog quantities Process Quantity Processing 5.2 A class of function functions for process industry automation (including flow rate, temperature, etc.) are provided. 5.3 Typical applications Typical links for controller design and control Typical Control Links system simulation are provided. PID Controller 5.
Description of environmental indicators Working temperature:-20~+50℃ Storage temperature:-25~+80℃ Anti-vibration:8.3-400hz 10mm 6.8g Shock resistance: 50g,6ms&11ms relative humidity:10%~95% Protection Level: IP65 Anti-jamming Performance of Electrostatic Discharge:Power-on mode Air Discharge±15kv, Contact Discharge±8kv,Power-off mode Air Discharge±25kv ,Contact Discharge±8kv Connect with external controller Connecting with external controller devices through CAN bus, supporting CAN2.
Common troubleshooting 1. The connection between the display case and the grounding metal parts should have a low impedance value. The following tests are carried out to determine whether they are qualified or not. During the transient interference injection, the voltage drop between the controller shell and the grounding metal parts is measured. It is required that the voltage Umax on the shell should not be greater than 0.
SECD-7I0A-35 User Manual Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.