User's Manual
Table Of Contents
- Contents
 - Version History
 - 1 Introduction
 - 2 Key features
 - 3 Terminal dimensions
 - 4 Installation
 - 5 Interface introduction
 - 6 Application Interface
 - 7 Electrical, Reliability and Radio Characteristics
 - 8 Software/ Firmware Upgrade
 - Appendix
 
        Smart Machine Smart Decision  
T5320+G_User Guide_V1.01 21 2013-04-15 
Table 10: AT+CADC Read ADC 
Description 
Read the ADC value from modem. We support 3 type of ADC, raw type, temperature type and voltage type. 
SIM PIN  References 
NO  Vendor 
Syntax 
Test Command  Responses 
AT+CADC=?  +CADC: (range of supported <adc>s) 
OK 
Write Command  Responses 
+CADC: <value> 
OK 
AT+CADC=<adc> 
ERROR 
Execution Command  Responses 
AT+CADC 
Same as AT+CADC= 0: 
+CADC: <value> 
OK 
Defined values 
<adc> 
ADC type: 
0 – raw type. 
1 – temperature type. 
2 – voltage type(mv) 
<value> 
Integer type value of the ADC. 
Examples 
AT+CADC=? 
+CADC:(0-2) 
OK 
AT+CADC=0 
+CADC: 187 
OK 
6.3.3  GPIO interfaces 
T5320+G provides 3 GPIO pins. All GPIOs can be configured as inputs or outputs. User can use AT Commands 
to read or write GPIOs status. Refer to document [1] for details. 