User's Manual
                                                                                                                                                  Smart Machine Smart Decision 
- 8 - 
RXD, TXD  ±2KV  ±8KV 
Antenna port  ±5KV  ±10KV 
SPK_P/SPK_N/ 
MIC_P/MIC_N 
±4KV  ±8KV 
PWRKEY  ±4KV  ±8KV 
Note:  It  is  suggested  that  customers  in  serials  with  100ohm  resistances  on  UART  lines  for  ESD 
consideration. 
4.  Radio Characteristics 
4.1.  Module GSM/GPRS Output Power 
The  following table shows the  module conducted output  power,  it is followed by  the 3GPP TS 05.05  technical 
specification requirement. 
Table 9: SIM808 GSM 900 and GSM 850 conducted RF output power 
GSM850、EGSM900 
Tolerance (dB) for conditions 
PCL  Nominal output power (dBm) 
Normal  Extreme 
5  33  ±2  ±2.5 
6  31  ±3  ±4 
7  29  ±3  ±4 
8  27  ±3  ±4 
9  25  ±3  ±4 
10  23  ±3  ±4 
11  21  ±3  ±4 
12  19  ±3  ±4 
13  17  ±3  ±4 
14  15  ±3  ±4 
15  13  ±3  ±4 
16  11  ±5  ±6 
17  9  ±5  ±6 
18  7  ±5  ±6 
19-31  5  ±5  ±6 
Table 10: SIM808 DCS 1800 and PCS 1900 conducted RF output power 
DCS1800、PCS1900 
PCL  Nominal output power (dBm)  Tolerance (dB) for conditions 