User's Manual
   Smart Machine Smart Decision 
SIM5360A_User_Manual_V1.03     2014-07-03 
32
Figure 20: Reference circuit of level shift 
To comply with RS-232-C protocol, the RS-232-C level shifter chip should be used to connect SIM5360A 
to the RS-232-C interface. In this connection, the TTL level and RS-232-C level are converted mutually. 
SIMCom  recommends  that  user  uses  the  SP3238ECA  chip  with  a  full  modem.  For  more  information 
please refers to the RS-232-C chip datasheet. 
Note: SIM5360A supports the baud rate: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 
115200, 230400, 460800, 921600, 3200000, 3686400, 4000000bps. Default rate is 115200bps. 
3.4  SD/MMC Interface 
SIM5360A provides one 4-bit SD/MMC interface. Its operation voltage is 2.85V, with clock rates up to 52 
MHz. It supports 1-bit SD/MMC or 4-bit SD data transmission mode. Though the same hardware 
controller is used, the initialization procession for SD or MMC cards is different. SIM5360A will detect 
which card is inserted automatically.
Note: Interface with SD/MMC memory cards up to 32GB. 
3.4.1  Pin Description 
Table 10: Pin description 
Pin name  Pin No.  Function 
SD_DATA0 
22 
SD/MMC card data0 
SD_DATA1 
23 
SD card data1 
SD_DATA2 
24 
SD card data2 
SD_DATA3 
25 
SD card data3 
SD_CLK 
26  SD card clock 
SD_CMD 
21  SD card command 