User's Manual

Keypad & Proximity Flash Mount Reader Installation Manual
once and the reader is in Ready mode.
2. Present the card. The Blue LED will flicker once; buzzer will beep once.
3. When card is present and read by the reader, blue back lit will flash once; and buzzer will
beep once as well. The card data will then transmit to the controller. After, weather the back lit
of the reader will remain ON or Flash or change to Green or Red color, this shall depend on
the Green and Red LED inputs.
4. For number pad reader, when a number is pressed and successfully detected, the back lit
under the number will flash 1 time and the buzzer will beep once. The number being pressed
will burst out by default (4 bits burst).
Physical Dimension:
Troubleshooting:
Trouble List Solution
No Response
when Power Up
z Discount the power and confirm that the power supply cable is
correctly connected (See “Wiring” above).
z Check the input voltage is sufficient (See “Specifications” above).
Auto Restart
z Check the input voltage is sufficient (See “Specifications” above).
Cannot read card
number correctly
z Check the format setting on the controller if it is the same as the card
format. Use approved card (known format and Facility Code) to test.
z Check if the shield cable is correctly connected to Classis Ground at
ONE point only.
Reader beeps but
No card data info
z Check if data 0 & data 1 cable is correctly connected (See “Wiring”
above).
z Check the input voltage at the card reader end is correct (See
“Specifications” above).
Buzzer error z Check if the buzzer cable is correctly connected (See “Wiring” above).
Back Lit Error
z Check the Led cable is correctly connected (See “Wiring” above).
z Use Default Configuration Card to set it back to normal.