User's Manual

UTT Technologies C hapter 8 User Management
http://www.uttglobal.com Page 134
8.1.2 An Example for Global Management Policy
A business uses a AC750W Wireless Router to access the Internet. The CEO wants to
block the employees from using MSN and BT applications during business hours (Monday
to Friday, 9:00 to 17:00).
The configuration steps are the following:
Step 1 Go to the User > Global Management page.
Step 2 Select the Block MSN and Block BT check boxes.
Step 3 Define business hours: clear the Everyday check box, next select the Mon,
Tue, Wed, Thu,andFri check boxes; clear the 24 Hours check box, next
choose 09:00 and 17:00 as the daily start time and end time respectively. The
above settings are shown in Figure 8- 3.
Step 4 Click the Save button to save your settings.
Figure 8-3 Global Management Policy - Example