Operator`s manual
REMOTE
PRODUCT
(D100)
yes: sets PRODUCT 0 – 20 remotely according input voltage 0-10V at terminal
AIN1..
Note:RefertoServiceManualfordetailedinformation.
Note:AvailableonlyforconveyorssuppliedbyCASSEL
Default: no
AUTOMATIC
TEACH (D105)
yes: only one product sample is required for the teach process. The conveyor
belt goes back and forth feeding the product through the sensor automati-
cally.
Note:MakesurethatCONV. LENGTH mm issetupcorrectly.
Default: no
CONV. LENGTH
mm (D110)
sets the length of the conveyor belt for AUTOMATIC TEACH.
Default: 1,000 [Millimetres], should be set to actual value
Range: 100 - 9,999 [Millimetres]
AUTO
FREQUENCY
(D115)
yes: In case of a two or four frequency sensor head the teach assistant chooses
automatically the best frequency automatically.
Default: no
TEACH PHOTO
mm (D117)
sets the distance from photo cell to sensor end.
Default: 999 [Millimetres], should be set to actual value
Range: 0 - 999 [Millimetres]
13.1.3. ADVANCED (MENU)
ADVANCED ✔ Level 3
Total 276 25 mV
Metal 34 12 % 154.26°
MENU
EXIT
TEST
IFS/HACCP
PRODUCT
MOZZARELLA
OK
5
METAL SENSE mV
122
PRODUCT X TOL.
1.0
PRODUCT Y TOL. 1.0
AMPLIFICATION X 100%
AMPLIFICATION Y 100%
ATTENUATION 1/1
PHASE 89.92
PHASE TRACK 0.00
The ADVANCED (MENU) is for experts only. Product parameters
are automatically set during the teach assistant. This menu
allows to modify the product parameters manually.
METAL SENSE
mV (D120)
sets the metal sensitivity and thus the threshold for metal detection. If set to
3000 mV metal detection for this product is deactivated and NOT ACTIVE is
displayed.
To determine which mV a particular metal object generates, refer to mV value
in the lower right corner of the display. Bear in mind that non-spherical metal
parts may generate different magnitudes depending on their orientation.
Magnetic metal parts produce a larger signal than non-magnetic metal parts.
Note:Normally,youonlyhavetosetMETAL SENSE mVforneutralprod-
ucts (PRODUCT IS... = neutral). The teach assistant presets METAL
SENSE mVforallotherproductsautomatically.
Default: set during
TEACH
Range: 3 - 3,000
68
METAL SHARK® 2 Operator’s Manual
Software Version 1.10a and higher