Operator`s manual
AMPLIFICATION
Y (D140)
Refer to AMPLIFICATION X.
ATTENUATION
(D145)
attenuates the signal received from the sensor head.
Default: 1/1
Values: 1/1, 1/3, 1/10
PHASE (D150)
The setting of the product phase helps to blank out any product effect. It is set
automatically during the TEACH process.
Note:PHASEisonlyavailablewithproduct1-120,notwithPRODUCT
000.
Default: 0.00°
PHASE TRACK
(D155)
adjusts the product's phase during normal operation to compensate slow
changes of the product effect phase. The product effect phase may change
depending on product temperature and composition.
The parameter PHASE TRACK indicates the increment with that the phase
is adjusted: The higher this value the stronger the phase tracking. E.g. a 0.10°
means 0.10 degree tracking with each product or metal signal.
Default: 0.00°
Range: 0.00 - 10.00°
70
METAL SHARK® 2 Operator’s Manual
Software Version 1.10a and higher